Siemens SIMATIC PANEL PC 877 Operating Instructions Manual page 209

Industrial pc
Hide thumbs Also See for SIMATIC PANEL PC 877:
Table of Contents

Advertisement

Assignment of the display to the display select pins
The display select inputs are used to configure one of 15 possible displays automatically.
The display select inputs are equipped with pull-up resistors, i.e., these inputs have a high
signal if they are not connected. The input must be connected to GND if a low signal is to be
generated.
Pin No.
LCD_SEL3
0
low
1
low
2
low
3
low
4
low
5
low
6
low
7
low
8
high
9
high
10
high
11
high
12
high
13
high
14
high
15
high
SIMATIC Panel PC 877
Operating instructions, Release 07/2006, A5E00877780-01
LCD_SEL2
LCD_SEL1
low
low
low
low
low
high
low
high
high
low
high
low
high
high
high
high
low
low
low
low
low
high
low
high
high
low
high
low
high
high
high
high
LCD_SEL0
Display type
low
reserved
high
1280x1024 (SXGA), TFT, 2
x 18-bit, LVDS channel 1
and 2
low
DVI LCD 640 x 480
high
DVI LCD 800 x 600
low
640 x 480 (VGA), TFT, 18
bits, LVDS channel 1
high
reserved
low
1024 x 768 (XGA), TFT, 18
bits, LVDS channel 1
high
800 x 600 (SVGA), TFT, 18
bits, LVDS channel 1
low
reserved
high
reserved
low
reserved
high
reserved
low
Reserved 1024 x 768
(XGA), TFT, 2 x 18-bit,
LVDS channel 1 and 2
high
DVI LCD 1024 x 768
low
DVI LCD 1280 x 1024
high
No LVDS display or DVI
LCD with automatic DDC ID
Detailed descriptions
17.1 Motherboard
17-17

Advertisement

Table of Contents
loading

Table of Contents