Siemens SIMATIC PANEL PC 877 Operating Instructions Manual page 111

Industrial pc
Hide thumbs Also See for SIMATIC PANEL PC 877:
Table of Contents

Advertisement

(1)
(2)
(3)
The description of the drivers and SOM software for Windows is available on the
"Documentation and Drivers" CD under Drivers/Tools >Tools>PPC877.
From the CD, run Install.bat and follow the instructions on your screen.
SIMATIC Panel PC 877
Operating instructions, Release 07/2006, A5E00877780-01
Temperature range
Here the current temperature and limit values are shown. You can
toggle the temperature display mode to indicate either the current
temperature, or the min./max. values measured since the start of the
application.
(1a)
(1b)
(1c)
Watchdog range
Here, you can configure the watchdog function in your monitoring
application. You can specify the watchdog time, activate a PC reset
and activate / deactivate the watchdog.
Fan area
You can read the current fan speed in this area.
(3a)
(3b)
11.2 Safecard on Motherboard (SOM)
Internal processor temperature
Device temperature beneath the power supply:
upper threshold can be set from 30°C to 80°C
Cooling air temperature surrounding the DVI connector:
- depending on device 3°C to 5°C higher than the ambient
temperature
- upper threshold can be set from 25°C to 55°C
Fan speed in the area close to the processor
Fan speed on the power supply
Functions
11-3