OPTION menu
Item
SERVICE
(continued)
54
RESPONSE LIMIT TIME
This menu is available only when the NETWORK
BRIDGE is selected for the COMMUNICATION
TYPE and the HALF-DUPLEX is selected for the
TRANSMISSION METHOD.
Select the time period to wait for receiving response
data from other devise communicating by the
NETWORK BRIDGE and the HALF-DUPLEX through
the CONTROL OUT port.
OFF ó 1s ó 2s ó 3s
OFF: Select this mode if it is not required to check the
responses from the devise that the projector sends data
to. In this mode, the projector can send out data from
the computer continuously.
1s/2s/3s: Select the time period to keep the projector
waiting for response from the device that the projector
sends data to. While waiting the response, the projector
COMMUNICATION
does not send out any data from the CONTROL OUT
(continued)
port.
NOTE
BYTES INTERVAL TIMEOUT
This menu is available only when NETWORK BRIDGE
is selected for the COMMUNICATION TYPE and HALF-
DUPLEX is selected for the TRANSMISSION METHOD.
Select the blank time length to judge that the response
data has finished in the communicating in the condition
of the NETWORK BRIDGE and the HALF-DUPLEX
through the CONTROL OUT port.
50ms ó 100ms ó 150ms ó 200ms
NOTE
Description
• OFF is selected as the default setting.
• 50ms is selected as the default setting.