Supported Configurations; System Build-Up Troubleshooting Procedure - HP Integrity BL870c User's & Service Manual

Blade
Hide thumbs Also See for Integrity BL870c:
Table of Contents

Advertisement

6.
To decode the blinking state of server LED, review the entire SEL and look at events with alert
level 2 and above.
For example:
Log Entry 24: 14 Feb 2003 15:27:02
Alert Level 3: Warning
Keyword: Type-02 1b0800 1771520
Hot Swap Cage: SCSI cable removed
Logged by: BMC;
Data1: Device Removed/Device Absent
0x203E4D0AC6020220 FFFF0008F61B0300
Log Entry 73: 00:00:12
Alert Level 3: Warning
Keyword: Type-02 050301 328449
The server's built-in sensors have detected an open chassis door.
Logged by: BMC;
Data1: State Asserted
0x200000000C020570 FFFF010302050300

Supported Configurations

This subsection provides examples of how to use the iLO 2 MP to acquire configuration information
for troubleshooting purposes. It also provides a system build-up procedure.
For a list of all FRUs in the server blade, with their corresponding part numbers, see
(page
143).

System Build-Up Troubleshooting Procedure

Use this procedure only when the server powers on and remains powered on but does not enter
into or pass POST, or does not boot to EFI menu.
1.
Remove the access panel to gain access to internal FRUs. See
Panel" (page
2.
Remove all of the HDDs from the front of the chassis. See
(page
111).
3.
Remove the memory DIMMs. See
4.
Remove the processors. See
5.
Replace the server blade in the enclosure. The server blade (and MP) powers on.
6.
Enter the DF command from the MP Console Menu. The following displays:
CM> DF
Display FRU Information Menu:
S - Specific FRU
A - All available FRUs
V - Display Mode: Text
7.
Enter S to show the FRU IDs. The following displays:
FRU IDs:
--------
0001-Comm Module
0003-Mezzanine Board
If you do not see all of the above FRU IDs, then concentrate on the missing FRU ID(s). The
following alert (IPMI) event displays for this action, as read from the SEL:
Log Entry 4: Dec 2005 00:00:09
Alert Level 7: Fatal
Keyword: Type-02 257100 2453760
Missing FRU device - DIMM0A
Logged by: Baseboard Management Controller,
104 Troubleshooting
Sensor: Cable / Interconnect - SCSI ChExt Cable
Sensor: Physical Security - Chassis Open
116).
"Removing a DIMM" (page
"Removing a Processor" (page
0002-Disk Backplane
0000-Motherboard
Appendix A
"Removing the Right Access
"Removing a SAS Disk Drive"
121).
125).

Hide quick links:

Advertisement

Table of Contents