Wiring; Line Voltage Wiring - Genie GCL-GCX Manual

Commercial line counter door operator
Hide thumbs Also See for GCL-GCX:
Table of Contents

Advertisement

Line Voltage Wiring Fig. 1
WARNING
DO NOT apply power to operator until instructed to do so.
The Genie® Company recommends that line voltage wiring
be performed by a qualified electrician.
Be sure that electrical power has been disconnected from the
input power wires being connected to the operator prior to
handling these wires. An appropriate lock-out /tag-out procedure
is recommended.
Line voltage wiring must meet all local building codes.
Make sure operator voltage, phase and frequency nameplate
ratings are identical to the job site line voltage ratings.
Input power wiring must be properly sized for the operators
amperage rating located on the nameplate.
To reduce the risk of electric shock, make sure the chassis of this
unit is properly grounded.
1) Remove LINE VOLTAGE INPUT PLUG and install proper
fittings and 1/2"conduit.
2) Route proper LINE VOLTAGE wires into operator.
3) Locate LINE INPUT terminals on circuit board. Using
correct connectors, attach wires to LINE INPUTS, and GROUND
terminal.
Keep low voltage and line voltage wires separate.
Route all line voltage wires as shown.
Plug all unused conduit holes.
GCL-GCX
Counter Door Operator
Section 5: Wiring
Figure 1
www.geniecompany.com