SATO /s8408 Operator's Manual page 89

Hide thumbs Also See for /s8408:
Table of Contents

Advertisement

MENU
NO
RETRY
RFID LABEL DATA
RELEASE
RETRY
0
S8400 Series Operator Manual
Unit 4: Printer Configuration
RFID USER MODE (TABLE 4-12)
Showing the total accumulated number of RFID writes.
SUCCESS: Shows the number of write success to RFID tag.
FAILURE: Shows the number of write failure to RFID tag.
TOTAL: Shows the total write quantity.
[Total quantity of successful writes] + [total quantity of write failures] = Total RFID Writes
The counters can be reset by performing a Factory Clear operation.
Showing the total number of RFID writes.
SUCCESS: Shows the number of write success to RFID tag.
FAILURE: Shows the number of write failure to RFID tag.
TOTAL: Shows the total number of writes.
[Total quantity of successful writes] + [total quantity of write failures] = Total RFID Writes
Initializing RFID current counter.
Selecting YES and pressing FEED button will initialize the RFID current counter
(SUCCESS, FAIL, or TOTAL).
The initial value is NO.
Note: The RFID life counter(s) cannot be reset through this screen.
Setting the printer motion at the time of RFID tag error. Also, this section shows how to
recover from an RFID ERROR state when the error count exceeds the specified limit.
RELEASE: The printer keeps writing tags and discarding defective tags up to a
specified quantity even when a tag error occurs. Then the printer emits a RFID ERROR
message and pauses the operation when the error count exceeds the specified limit.
RETRY: When a tag error occurs, the printer attempts to write the same data based on
the specified quantity. If the tag writing still fails, the printer emits a RFID ERROR
message and pauses the operation.
The initial value is RETRY.
This screen is displayed only when MODULE SELECT is set to ThingMagic in the
Service Mode.
Allows the selection of the printer's action following a write failure. The RELEASE
option
deletes the current job so the printer may advance to next print job. Choosing the
RETRY option instructs the printer to continue attempting to write the same data until it
succeeds or until an error (MAX ERR CNT) occurs.
Use the printer's operator panel to scroll and select the desired option.
Setting the counter for void and reprint tags at the time of tag error.
Input range is from 0 to 9.
The initial value is 0.
DESCRIPTION
4-43