SATO /s8408 Operator's Manual page 83

Hide thumbs Also See for /s8408:
Table of Contents

Advertisement

MENU
BCC CHECK
ENABLE
DISABLE
WIRELESS MODE
802.11 Ad Hoc
Ad Hoc
Infrastructure
SSID
X
CHANNEL
XX
MENU
SERVICE MODE
SENSOR LEVEL
I-MARK
X.XV
LEVEL OFFSET
XX
SENSOR LEVEL
I-MARK
X.XV
SLICE LEVEL
XX
SENSOR LEVEL
GAP
X.XV
LEVEL OFFSET
XX
SENSOR LEVEL
GAP
X.XV
SLICE LEVEL
X.XV
AUTO ONLINE FEED
YES
NO
S8400 Series Operator Manual
Unit 4: Printer Configuration
WIRELESS LAN INTERFACE MODE (TABLE 4-8)
Allows BCC check to be enabled or disabled. Will only appear if STATUS5 is set for protocol.
When the printer driver is set for GAP sensor printing (transmissive mode), BCC CHECK will be
switched to DISABLE.
When performing a test print of any LAN type of interface, set this to DISABLE.
This menu screen allows for the setting of the wireless LAN communication method. See your
network administrator for the proper setting.
Allows the unique wireless LAN SSID name to be configured in the printer. See your network
administrator for proper SSID settings.
Allows the wireless LAN channel to be set in the printer. The valid range is 01 to 14. See your
network administrator for the wireless network channel.
SERVICE MODE (TABLE 4-9)
The Service Mode allows the programming of various dimensional settings, sensor thresholds,
and language options.
Permits sensitivity adjustment of the eye-mark sensor. The adjustment range is 1 to 99. The
default value is 50.
Permits adjustment of the sensor's slice level. The slice level is the voltage at which the printer
determines media change from label to gap and vice-versa.
A setting of 0.0 to 3.2 volts is possible. The default is 1.4 volts. A setting of 0.0 volts causes the
printer to automatically determine the slice level.
Allows sensitivity adjustment of the gap sensor for different label materials. Increasing/
decreasing the level offset changes the sensor's voltage value within a factory set range.
The adjustment range is 1 to 99. The default value is 50. Refer to the Adjustment Procedures
section of this manual for detailed instructions.
Allows the sensor threshold (slice level) adjustment of the gap sensor. Ideally, the slice level
setting is at or near the mid-point between the low and high voltage readings from the previous
screen ((low voltage reading + high voltage reading)/2 = slice level setting).
A setting of 0.0 to 3.2 volts is possible. The default value is 1.2 volts. A setting of 0.0 volts causes
the printer to automatically determine the slice level.
This feature allows one label to be fed upon the printer entering the online mode. Enable or
disable as desired.
DESCRIPTION
DESCRIPTION
4-37
PN: 9001160 (C)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S8412S8424

Table of Contents