Vertical Term. 0,2 Or 4 45° Offsets (6-5/8") - FireplaceXtrordinair 36 DV EFIII Owner's Manual

Built-in direct vent fireplace
Hide thumbs Also See for 36 DV EFIII:
Table of Contents

Advertisement

Installation
2 0
Vertical Terminations with 0, 2, or 4 45° Offsets using 6-5/8" Dia. Vent
Use 6-5/8" diameter co-axial vent
A Maximum of Four 45° Elbows May be Used
10' Minimum System Height (with or without offsets)
40' Maximum System Height
12' 8" Maximum Horizontal Offset
Offset Length
None
1' Section
2' Section
3' Section
4' Section
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor position.
Zero or Two 45° Offsets
40' (max)
35 feet
30 feet
25 feet
20 feet
15 feet
10 feet
(min.)
5 feet
0 feet
Travis Industries
Hor. Offset
Vert. Rise
5"
1'
1' 9"
2' 5"
3' 2"
Restrictor
Position # 7
NOTE:
Restrictor positions are based upon lab tests. The
ideal restrictor position may vary slightly, especially
when the termination is near the demarkation line.
Restrictor
Position # 1
NOTE:
The maximum offset lengths,
combined, is four 4' sections.
(for qualified installers only)
1'
1' 7"
2' 4"
3'
3' 8"
40' (max)
40' (max)
35 feet
35 feet
30 feet
30 feet
25 feet
25 feet
20 feet
20 feet
15 feet
15 feet
10 feet
10 feet
(min.)
(min.)
5 feet
5 feet
0 feet
0 feet
4040708
Horizontal
Offset
Vertical
Rise
Offset
Length
Four 45° Offsets
Restrictor
Position # 7
NOTE:
Restrictor positions are based upon
lab tests. The ideal restrictor position
may vary slightly, especially when the
termination is near the demarkation
line.
Restrictor
Position # 1
NOTE:
The maximum offset
lengths, combined, is
four 4' sections.
1 0 0 - 0 1 1 6 0
40' (max)
35 feet
30 feet
25 feet
20 feet
15 feet
10 feet
(min.)
5 feet
0 feet