Mantel Requirements - FireplaceXtrordinair 36 DV EFIII Owner's Manual

Built-in direct vent fireplace
Hide thumbs Also See for 36 DV EFIII:
Table of Contents

Advertisement

Installation
1 6

Mantel Requirements

The combustible area above the facing must not protrude more than 3/4" from the facing. If it does, it
is considered a mantel and must meet the mantel requirements listed in this manual.
Non-Combustible
Mantels
Travis Industries
Combustible Mantels
Max.
Mantel
Depth is
8"
30" Arch face
28-1/2" Rectangular face
30-3/8" Architectural face
Max.
Mantel
Depth is
8"
4040708
(for qualified installers only)
Combustible Mantel
Non-Combustible mantels must maintain a 12"
clearance to the top of the face and be located
below the header -or- maintain a 24" clearance.
Non-Combustible Mantel
Header
46-1/8"
30" Arch face
28-1/2" Rectangular face
30-3/8" Architectural face