Optional Equipment
5
Install the logs and
embers.
6
Replace glass and
face.
7
Remove the regulator
from the front of the
gas control valve.
Replace with the
propane regulator,
using the new gasket
and screws included
with the regulator.
NOTE: Leak test
this area after the
heater is installed,
gas is connected,
and the main
burner is lit.
9
Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly leak-
test all gas connections and the gas control valve. Check the pilot. Adjust if necessary.
WARNING:
When lighting or re-lighting the pilot, the glass must be removed (see
page 27).
To adjust the pilot flame, turn this screw (NOTE: if totally
unscrewed gas will come out of this port). Clockwise
lowers the flame while counter-clockwise raises it.
Travis Industries
a
Remove and discard the three
screws using a slotted screwdriver
of Torx T-20.
Slotted
Screwdriver
(or T-20 Torx)
c
Install the LP regulator. Use
the screws included with the
LP regulator. Tighten to
approximately 25 Lbs. torque.
Slotted
Screwdriver
(or T-20 Torx)
The pilot flame must contact the thermocouple and
thermopile (see the illustration below). Adjust the pilot up or
Standard
down as necessary.
Screwdriver
4040708
(for qualified installers only)
b
Remove and discard the
regulator, diaphram, spring
and center post.
NOTE: Make sure the
regulator gasket is correctly
aligned before installation.
Place the LP
label on the base
of the fireplace
near the gas
control valve.
4 5
d
1 0 0 - 0 1 1 6 0