3 – Getting Started
Installing InfiniBand on the Remaining Servers
If any switch fails to be updated, use the "View ibtest result files" option to review
the result files from the update. Refer to the section "Interpreting the ibtest log files"
on page 5-68 for more details.
If some switches were not found review the following for those switches which were
not found:
Is switch powered on
❥
Is switch connected to IB network
❥
Is Management node connected to the IB network
❥
Is the SM running on the IB network
❥
Is correct set of switches listed in the ibnodes file (the previous step may be
❥
repeated to review and edit the file as needed)
7. (Switch) If any 9024FC switches were skipped above in step 5 and 6, these
steps should be repeated for those switches. In this case it is recommended
to create a separate file with a name other than ibnodes. An alternate name
may be specified at the prompt:
Select Switch File to Use/Edit
[/etc/sysconfig/iba/ibnodes]:
3.7
Installing InfiniBand on the Remaining Servers
Fast Fabric may now be used to install and configure the remaining hosts and verify
overall operation of the fabric.
1. (Linux) Select the "Host Setup via Fast Fabric" option from the main menu.
2. Select the items shown as "Perform" in the menu below and press the P key
to perform them:
3-12
Q
D000006-000 Rev A