The location should be easy to reach for opening and dosing.
A
C
E
B
D
A. _/t#' flexible
gas connector
B. _/J pipe
to flare adapter
fitting
C. J/_" NPT minimum
p/ugged
tapping
D. _/J" NPT gas supp/y
fine
E. Gas shutoff
va/ve
Gas supply connection
requirements
Use an e[bow and
a 3/8H
flare
x
@/8 u
NPT adapter fitting
between
the f[exib[e
gas connector
and the dryer gas pipe, as needed
to avoid kinking.
Use only pipe-joint compound.
Do not use TEFI.ON "_* t ape.
This dryer must be connected
to the gas supply
line with
a listed flexible
gas connector
that complies
with the standard
for connectors
for gas appliances,
ANSI Z21.24
or
CSA 6.10.
Burner Input Requirements:
Elevations above 10,000
ft (3,048
m):
When
installed
above 10,000
ft (3,048
m) a 4% reduction
of the burner
Btu rating shown
on the model/serial
number
plate is required
for each 1,000 ft (305 m) increase
in
elevation.
Gas Supply Pressure Testing
The dryer must be disconnected
from the gas supply
piping
system during
pressure testing
at pressures greater than _/_psi.
Dryer Gas Pipe
The gas pipe that comes
out through
the rear of your dryer has
a
3/sll
male pipe thread.
(1.9 cm)
A. ;/8" NPT dryer pipe
Fire Hazard
Use a heavy
metal
vent.
Do not use a plastic
vent.
Do not use a metal
foil vent.
Failure
to follow
these
instructions
can result
in death
or fire.
WARNING:
To reduce
the risk of fire, this dryer MUST
BE EXHAUSTED
OUTDOORS.
IMPORTANT:
Observe
all governing
codes and ordinances.
The dryer exhaust
must not be connected
into any gas vent, chimney,
wall, ceiling,
or a
concealed
space of a building.
If using
an existing
vent
system
Clean
lint from the entire
length of the system and make sure exhaust
hood
is not plugged
with
[int.
Replace any plastic
or metal foil vent with
rigid or flexible
heavy metal vent.
Review Vent system chart. Modify
existing
vent system if necessary
to achieve
the best
drying
performance.
If this is a new vent system
Vent
material
Use a heavy metal vent. Do not use plastic
or metal foil vent.
t®TEF[
ON
is a registered
trademark
of E.[. Du Pont De Nemours
and
Company.