Maytag MGDB980BW0 Installation Instructions Manual
Maytag MGDB980BW0 Installation Instructions Manual

Maytag MGDB980BW0 Installation Instructions Manual

Gas and electric dryers
Table of Contents

Advertisement

Available languages

Available languages

Gas Dryer
Installation
Instructions
Canadian
Electric
Dryer
Installation
Instructions
Instructions
pour
l'installation
de la s6cheuse
h gaz
p
(E.-U. et Canada)
et 61ectrique
(Canada
uniquement)
Table
of Contents
................................................................
2
....................................
4
Tools and Parts ....................................................................
4
.....................................................
5
ONLY ........... 6
GAS DRYER POWER HOOKUP .................................................
7
INSTALL LEVELING LEGS ..........................................................
9
.........................................................
9
VENTING ....................................................................................
10
Venting Requirements .......................................................
10
Plan Vent System ...............................................................
11
Install Vent System ............................................................
12
INLET HOSES .........................................................
12
CONNECT VENT .......................................................................
14
LEVEL DRYER ...........................................................................
14
iNSTALLATiON CHECKLIST ...............................
15
REVERSE DOOR SWING ..........................................................
15
Table
des
matibres
........................................
17
.......................................
19
Outillage et pi_ces .............................................................
19
...............................................
20
leLECTRIQUE - CANADA SEULEMENT ...................................
21
A GAZ ..........................................................................................
22
...................... 23
RACCORDEMENT
AU GAZ .......................................................
25
L'EVACUATION ...........................................................................
25
concernant I'evacuation .................................
25
des circuits de conduits ..............................
26
Installation du syst_me d'6vacuation ...............................
28
DES TUYAUX DE VIDANGE ...................... 28
DU SYSTl=ME DqeVACUATION ................. 30
leTABLIR L'APLOMB
DE LA SLeCHEUSE ..................................
30
DE LA PORTE ............ 31
Para obtener acceso al "lnstrucciones
de instalaci6n" en espaSol, o para obtener informaci6n
adicional acerca de su producto, visite: www.whirlpool.com
Tenga listo su nOmero de modelo completo. Puede encontrar el nOmero de modelo
y de serie dentro de la cavidad superior de la puerta.
iNSTALLATiON
NOTES
Date of purchase:
Date of installation:
Installer:
Model number:
Serial number:
NOTES
CONCERNANT
L'INSTALLATION
Date d'achat
:
Date d'installation
:
Installateur
:
Num6ro de module :
Num6ro de s6rie :
W10562336A
W10562340A=SP

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MGDB980BW0 and is the answer not in the manual?

Questions and answers

Oscar Garza
February 16, 2025

Do you have to connect the steam

1 comments:
Mr. Anderson
February 16, 2025

No, connecting the steam feature is not required. If you are not using the steam function, you can skip the step related to connecting the cold water faucet.

This answer is automatically generated

Subscribe to Our Youtube Channel

Summary of Contents for Maytag MGDB980BW0

  • Page 1: Table Of Contents

    Gas Dryer Installation Instructions Canadian Electric Dryer Installation Instructions Instructions pour l'installation de la s6cheuse h gaz (E.-U. et Canada) et 61ectrique (Canada uniquement) Table of Contents Table matibres DRYER SAFETY ..............SF:CURITE DE LA S¢:CHEUSE ........INSTALLATION REQUIREMENTS ........EXIGENCES D'INSTALLATION ........
  • Page 2: Dryer Safety

    DRYER SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word "DANGER"...
  • Page 3 WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, or to prevent property damage, personal injury, or death. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 4: Installation Requirements

    INSTALLATION REQUIREMENTS TOOLS AND PARTS Tools needed for gas installations: Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. Tools needed for all installations: 8" (203 mm) or 10" 8"...
  • Page 5: Location Requirements

    INSTALLATION CLEARANCES LOCATION REQUIREMENTS The location must be large enough to allow the dryer door to open fully. DRYER DiMENSiONS Models with riser 22t/4 ''-_ 30"-_ (565 ram) (783 ram} 4" 441/2" Explosion Hazard (102 (1t30 ram) 63/4" 53/8" Keep flammable materials and vapors, such as --__j...
  • Page 6: Electric Dryer Power Hookup-Canada Only

    Spacingfor recessed area or closet insta(lation ELECTRIC DRYER All dimensions show recommended spacing allowed, with tested POWER HOOKUP- CANADA ONLY spacing of 0" (0 mm) clearance on sides and rear. ELECTRICAL REQUIREMENTS Additional spacing should be considered for ease of installation and servicing.
  • Page 7: Gas Dryer Power Hookup

    GAS SUPPLY REQUIREMENTS GAS DRYER POWER HOOKUP ELECTRICAL REQUIREMENTS Explosion Hazard Use a new CSA International approved gas supply line. Electrical Shock Hazard Install a shut-off valve. Plug into a grounded 3 prong outlet. Securely tighten all gas connections, Do not remove ground prong. If connected to LP, have a qualified person make sure...
  • Page 8 LP Gas Conversion: GAS SUPPLY CONNECTION REQUIREMENTS Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting IMPORTANT: Conversion must be made by a qualified between the flexible gas connector and the dryer gas pipe, technician. as needed to avoid kinking. No attempt shall be made to convert the dryer from the gas Use only pipe-joint compound.
  • Page 9: Install Leveling Legs

    INSTALL LEVELING LEGS MAKE GAS CONNECTION Connect gas supply to dryer Excessive Weight Hazard Use two or more people to move and install dryer. Failure to do so can result in back or other injury. Flared Non-flared male fitting male fitting Prepare dryer for leveling legs Remove red cap from gas pipe.
  • Page 10: Venting

    Exhaust hoods: VENTING [] Must be at least 12" (305 mm) from ground or any object VENTING REQUIREMENTS that may obstruct exhaust (such as flowers, rocks, bushes, or snow). Recommended Styles: Fire Hazard Louvered Hood Box Hood Use a heavy metal vent, Do not use a plastic vent.
  • Page 11: Plan Vent System

    If you prefer, dryer may be converted to exhaust through PLAN VENT SYSTEM the bottom. You must contact your local dealer to have dryer converted. Recommended exhaust installations Typical installations vent the dryer from the rear of the dryer. Other installations are possible. A ......
  • Page 12: Install Vent System

    Determine vent path: INSTALL VENT SYSTEM [] Select route that will provide straightest and most direct path outdoors. Install exhaust hood [] Plan installation to use fewest number of elbows and turns. [] When using elbows or making turns, allow as much room as possible.
  • Page 13 Attach short hose and "Y" connector valve and tighten coupling (279 ram) If space permits, attach the female end of the "Y" connector to the cold water faucet. See figure A. Attach other end of long hose If "Y" connector cannot be attached directly to the cold water to fill valve at bottom of dryer faucet, the short hose must be used.
  • Page 14: Connect Vent

    CONNECT VENT LEVEL DRYER Level Dryer , Connect vent to exhaust outlet level here Place Place level here Using a 4" (102 mm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing vent, make sure vent is clean.
  • Page 15: Complete Installation Checklist

    COMPLETE INSTALLATION REVERSE DOOR SWING CHECKLIST You can change your door swing from a right-side opening to a left-side opening, if desired. [_ Check that all parts are now installed. If there is an extra part, go back through steps to see what was skipped. 1.
  • Page 16 Reverse strike 4. Install the two hinges to the front panel of the dryer using 4 screws. Use the non-slotted side to attach the hinge 1. Remove the door strike (A) from the dryer door opening. to the front panel. 2.
  • Page 17: Sf:curite De La S¢:Cheuse

    S]_CURIT]_ DE LA S]_CHEUSE Votre s_curit_ et celle des autres est tr_s irnportante. Nous donnons de nombreux messages de securit6 importants dans ce manuel et sur votre appareil m6nager. Assurez-vous toujours lire tousles messages de s6curit6 et de vous y conformer. Voici le symbole d'alerte de s_curit&...
  • Page 18 AVERTISSEMENT : Pour votre s6curit6, les renseignements dans ce manuel doivent _tre observ6s pour r6duire au minimum les risques d'incendie ou d'e×plosion ou pour _viter des dommages au produit, des blessures ou un d6c_s. - Ne pas entreposer ou utiliser de I'essence ou d'autres vapeurs ou liquides...
  • Page 19: Exigences D'installation

    EXIGENCES D'INSTALLATION OUTILLAGE ET Pll_CES Rassembler les outils et pieces n6cessaires avant d'entreprendre I'installation. Lire et observer les instructions foumies avec chacun des outils de la liste ci-dessous. Outils n_cessaires _ toutes les installations Compos6 d'6tanch6it6 raccords filet6s - r6sistant au gaz propane Pi_ces fournies...
  • Page 20: Exigences D'emplacement

    DISTANCES DE Df=GAGEMENT A RESPECTER POUR EXIGENCES D'EMPLACEMENT L'INSTALLATION L'emplacement dolt 6tre assez grand pour permettre d'ouvrir completement la porte de la s6cheuse. DiMENSiONS DE LA S¢:CHEUSE Mod_Jesavec talon (565 ram) Risque d'explosion 4" 441/2" (102 ram) Garder les maii_res et les vapeurs inflammables, ielle (1130 ram)
  • Page 21: Raccordement De La Secheuse

    Autres crit_res _ respecter pour une installation Espacement pour une installation darts en r_sidence mobile un encastrement ou darts un placard Toutes les dimensions indiquent le d6gagement autoris6, avec "routes les s6cheuses un d6gagement test6 de 0" (0 mm) de chaque c6t6 eta I'arriere. Un systeme d'6vacuation en m6tal est disponible a I'achat chez votre revendeur.
  • Page 22: Raccordement Electrique De La Secheusea Gaz

    En cas d'utilisation d'un cordon de rechange, il est recommand6 RACCORDEMENT LECTRIQUE d'utiliser le cordon d'alimentation de rechange - piece num6ro DE LA SECHEUSE A GAZ 9831317. SPECIFICATIONS €:LECTRIQUES Pour plus d'informations, consulter les num6ros de d6pannage dans la section "Assistance ou service"...
  • Page 23: Installation Des Pieds De Nivellement

    SPC:CIFICATIONS DE L'ALIMENTATION EN GAZ Conversion pour I'alimentation au propane iMPORTANT : Un technicien qualifi6 doit effectuer la conversion. Ne pas entreprendre de convertir la s6cheuse dans le cas d'une utilisation avec un gaz diff6rent de celui indiqu6 sur la plaque signal6tique sans d'abord consulter la compagnie de gaz.
  • Page 24 SPI_CIFICATIONS DU RACCORDEMENT INSTALLATION DES PIEDS DE L'ALIMENTATION EN GAZ NIVELLEMENT Utiliser un coude et un adaptateur NPT de 3/8" x 3/8" entre le connecteur de gaz flexible et la conduite de gaz de la s6cheuse, tel que n6cessaire pour 6viter le pincement. Utiliser uniquement un compos6 d'6tanch6it6 ruban TEFLON tuyauteries.
  • Page 25: L'evacuation

    L'EVACUATION RACCORDEMENT AU GAZ EXIGENCES CONCERNANT L'I_VACUATION Raccorder i'alimentation en 9az la s6cheuse Raccord Raccord m&le m&le non conique conique Risque d'incendie Utiliser un conduit d'_vacuation en rn_tal Iourd. Ne pas utiliser un conduit d'_vacuation en plastique, Retirer le capuchon rouge de la canalisation de gaz.
  • Page 26: Planification Des Circuits De Conduits

    Clapets d'_vacuation Une mauvaise _vacuation de I'air peut causer de [] Dolt se trouver & au moins 12" (305 mm) du plancher ou I'humidit_ et une accumulation de charpie _ I'int_rieur de de tout objet susceptible d'obstruer I'ouverture d'6vacuation la maison, ce qui peut provoquer (tels des fleurs, des pierres, des buissons ou de la neige).
  • Page 27 Trousse d'obturation pour 6vacuation (pour couvrir les trous Dispositions sp_ciales pour les installations d'6vacuation inutilis6s)" Piece num@o W10186596 --Tous en r_sidence mobile les modeles Le syst_me d'6vacuation doJt _tre solidement fix6 a une section non combustible de la structure de la r6sidence mobile et ne doit Trousse d'6vacuation par le bas -- Piece num@o 8212503 passe terminer en dessous de la r6sidence mobile.
  • Page 28: Installation Du Syst_Me D'6Vacuation

    RACCORDEMENT DES TUYAUX Tableau des syst_rnes d'_vacuation VIDANGE de Mayta9 Pour les modeles h fonctionnement sans vapeur, passer Nornbre Type de Clapets Hottes directement a la section "Raccordement du systeme de coudes conduit d'_vacuation d'_vacuation d'6vacuation". 90 ° d'_vacuation de type inclines boite ou La s6cheuse dolt _tre connect6e au robinet d'eau froide...
  • Page 29 Serrer ies raccords "_ Fixer le long tuyau a I'_lectrovanne de remplissage de la s_cheuse et setter les raccords 33/4" (27g rnrn) (g5 rnrn) Terminer le serrage des raccords de deux tiers de tour Fixer I'autre extremite du long tuyau supplementaire avec une pince.
  • Page 30: Raccordement

    RACCORDEMENT DU SYST]_ME I_TABLIR L'APLOMB DE LA D'EVACUATION S]_CHEUSE R6glage de I'aplomb de la s_cheuse " . Raccorder le conduit d'6vacuation au clapet d'6vacuation P'_ cert lee_ Placer le niveau & cet endroit /_ I'aide d'une bride de fixation de 4" (102 mm), relier le conduit d'6vacuation a la bouche d'6vacuation de la s6cheuse.
  • Page 31: Achever L'installation Liste De Vlerification

    INVERSION DU SENS ACHEVER UINSTALLATION LISTE DE VERIFICATION D'OUVERTURE DE LA PORTE [_ V6rifier que toutes les pieces sont maintenant install6es. S'il Le sens d'ouverture de la porte peut 6tre chang6 du c6t6 droit reste une piece, passer en revue les diff6rentes 6tapes pour au c6t6 gauche, si d6sir6.
  • Page 32 inversion de la g&che 4. Installer les deux charnieres sur le panneau avant de la s6cheuse & I'aide de 4 vis. Utiliser le c6t6 sans fente pour fixer 1. Retirer la g&che de la porte (A) de I'ouverture de la porte la charniere sur le panneau avant.

Table of Contents