Chapter 6
Installing and Removing a SPA
Figure 6-5

Installing a SPA in a SIP

The system can indicate a hardware failure if you do not follow proper procedures or you remove a SPA
Caution
while the software configuration is being applied. After you remove a SPA, wait at least 15 seconds
before installing another SPA in the same subslot.
To install a SPA in a SIP, see
Locate the guide rails inside the SIP that hold the SPA in place. They are at the top left and top right of
Step 1
the SPA slot and are recessed about an inch, as shown in
Note
Carefully slide the SPA all the way into the SIP until the SPA is firmly seated in the SPA interface
Step 2
connector. When fully seated, the SPA might be slightly behind the SIP faceplate.
OL-17439-01
Securing a SPA in a SIP—Vertical Orientation
Figure 6-2
Insert the SPA so that the blank side of the SPA is facing up, when being inserted into a SIP that
is not installed in the Cisco CRS-1 router. The blank side of the SPA should be facing to the right
when the SPA is inserted into a SIP that is installed in the Cisco CRS-1 router. Note the