INTERFACE SPECIFICATION
1. RS-232 Pin assignment
EDR1640/920 can be controlled by external devices through RS-232 interface.
Pin assignment 9-pin RS-232 plug
1
2
3
4
5
6
7
8
9
DVR
PIN
NAME
1
FREE
2
TXD
3
RXD
4
FREE
5
SIGNAL GROUND
6
FREE
7
FREE
8
FREE
9
FREE
RS-485 pin assignment
Both RS-485 sockets are equally wired.
Pin 1: GND
Pin 3: RS485 + (A)
Pin 6: RS485 - (B)
2. Interface settings
For the RS232/485 port, 6 different speeds are available: 1200, 2400, 4800, 9600, 19200 and
38400 baud. Define the port settings in the RS232/RS485 menu.

APPENDIX B: Interface specification

HOST
PIN #
NAME
1
FREE
2
RXD
3
TXD
4
FREE
5
SIGNAL GROUND
6
FREE
7
FREE
8
FREE
9
FREE
1 2 3 4 5 6 7 8