Epson EM07ZS1647F User Manual page 125

Rc+ option fieldbus i/o
Table of Contents

Advertisement

4.2.1.2 Check Network Status
First of all, you should check the current condition of the network. There are different
specifications of status display LED on a device in the PROFIBUS DP standard. This section
explains how to check the network status assuming that EPSON RC+ is configured as a
master or slave.
(1) Master Status: BF/ST LEDs
BF (Physical error)
ST (Communication Status)
(2) Station Number of Absent Slaves
Absent slaves are disconnected from or not added to the network.
1. See the status flag regarding to the removal and addition if the master has status
2. See the BF/ST LEDs of all slaves if the master has no status information.
(3) Absent Slave Status: BF/ST LEDs
BF (Physical error)
ST (Communication Status)
(4) Physical Node Location of Absent Slave
Master
Start the examination from this block
when an error occurred here.
(5) Error Occurrence Condition
Immediate occurrence (high reproducibility)
Rare occurrence (low reproducibility)
Fieldbus I/O Rev.6
LED
information.
LED
PLC
Terminating Resistor ON
Slave
Slave
Terminating
Resistor ON
Slave
4. Troubleshooting (PROFIBUS DP)
Color
Green
Red
Green
Red
Color
Green
Red
Green
Red
Slave
Terminating Resistor ON
Slave
Slave
Light Condition
ON
Blinking
ON
Blinking
Light Condition
ON
Blinking
ON
Blinking
OFF
OFF
OFF
OFF
113