Rc+ option fieldbus i/o
Table of Contents

Advertisement

2. Installation
Maximum Network Length (Maximum Trunk Length)
The maximum network length is the longest distance either between terminating resistors or
between the two most distant nodes on the network.
Terminating
Resistor
The maximum network length is restricted by the type of cable and the baud rate.
Baud Rate
Both Thick Cable and Thin Cable can be combined and used for trunk lines. In this
case, the maximum network length is calculated using the following formulas.
Baud Rate
Drop Line Length
The drop line length is the distance from a branch on the trunk line to the end of that branch.
1 m
Node 1
In figure above, each drop line length is as follows:
Drop Line to Node 1: 4 m
Drop Line to Node 2: 6 m
Drop Line to Node 3: 6 m
One drop line length should be 6m or less.
14
The longest distance is the maximum network length.
Trunk Line
500 kbps
250 kbps
125 kbps
500 kbps
Thick Cable Length + Thin Cable Length ≤ 100m
250 kbps
Thick Cable Length + 2.5 × Thin Cable Length ≤ 250m
125 kbps
Thick Cable Length + 5.0 × Thin Cable Length ≤ 500m
Trunk Line
2 m
1 m
4 m
3 m
Node 3
Node 2
Terminating
Resistor
Maximum Network Length
Thick Cable
100 m
250 m
500 m
Maximum Network Length
Thin Cable
100 m
100 m
100 m
Fieldbus I/O Rev.6