2.9.4 Board Installation

Make sure that the power is turned OFF before installing/removing any boards
or connecting/disconnecting any cables.
connecting/disconnecting any cables with the power ON is extremely hazardous
WARNING
and may result in electric shock and/or malfunction of equipment.
(1) Configure the board address jumper (JP1) on each board. The board number must
(2) Install the board(s) in any available PCI slot in the controller.
(3) Connect the board(s) to the Fieldbus.
(4) Start the controller.
(5) The Windows Hardware Wizard will display a message that the applicomIO board
(6) Start the applicomIO console application.
(7) Click the Add Board button on the upper left of the console window to add a board.
Fieldbus I/O Rev.6
start with 1 consecutively. Refer to the following table for JP1 configuration.
Short Socket
Board No.
1
2
3
4
5
6
7
8
was found and prompt you to restart the computer.
The applicomIO console application will automatically start for this first start after
installation. Close this application for now and restart the controller.
Installing/removing any boards or
C0
C1
0: Short
0: Short
1: Short
0: Short
0: Short
1: Short
1: Short
1: Short
0: Short
0: Short
1: Short
0: Short
0: Short
1: Short
1: Short
1: Short
2. Installation
C2
0: Short
0: Short
0: Short
0: Short
1: Short
1: Short
1: Short
1: Short
57