Epson EM07ZS1647F User Manual page 120

Rc+ option fieldbus i/o
Table of Contents

Advertisement

4. Troubleshooting (DeviceNet)
108
(2) Select the DeviceNet (Scanner) tab. The window changes as shown below.
MAC ID
Module/NetWork LED
IO LED
applicomR Status
The scanner board status is shown in the "Code No. => Comment" form. The
code numbers are shown in the following table.
Status Code
General
Protocol
0
4
32
33
34
36
: MAC ID specified for the scanner board
:
Network Status (NS) LED status
: Module Status (MS) LED status
: Scanner board status
Descriptions
No fault detected. The function was performed
correctly.
Inaccessible data.
Additional information:
The remote device is in error.
Check its status.
Indicates that the parameters passed to the functions
are not correct (eg: Number of requested variables
too large)
Response time-out fault.
Additional information:
The device does not answer. Check its status and the
wiring.
The DeviceNet master has no device to be scanned in
its configuration.
Physical defect on the line.
Additional information:
No +24V power supply was detected.
The CAN component of the applicomIO® interface
is "Bus Off".
Check the network wiring and Baud Rate.
Device not configured.
Define the device configuration with the
applicomIO® Console and re-initiate the
initialization of the applicomIO® product by running
the PcInitIO
Fieldbus I/O Rev.6