Devicenet Board Installation; Board Appearance; Specifications - Epson EM07ZS1647F User Manual

Rc+ option fieldbus i/o
Table of Contents

Advertisement

2. Installation
2.9 EtherNet/IP Board Installation
Following two board types can be used for the fieldbus I/O option EtherNet/IP.
- PCU-ETHIO

2.9.1 Board Appearance

Part names and functions of the scanner board are shown in the following figure. For details
of the status display LEDs, refer to the 4. Troubleshooting in this manual.
PCU-ETHIO
(Do not use this port.)

2.9.2 Specifications

Part Number
Modes
Baud Rates
Interface
Maximum Node
Connection Type
Explicit messaging
EDS support
Input Data Size
Output Data Size
Automatic Detection
54
4-pin Terminal
Watchdog Port
LED (2)
(Not in use)
D-Sub 9 pin
(Not in use)
Status Display LED (2)
EtherNetI/P Connector
applicom PCU-ETHIO
Master/Slave
10, 100 Mbps
EtherNet/IP 1 port
127
Cyclic, Change of State
Yes
Yes
1 to 505 bytes
1 to 509 bytes
Yes. Devices can be detected automatically.
Jumper for Board Address
JP1
Fieldbus I/O Rev.6
JP1
0
1
C0 C1 C2