8.10.6 CF_LOGO Command

Command
"CF_LOGO_%1_%2" [CR]
%1
"0000 – 9999" ------------- Directly set Logo PIN code
"OFF" ---------------------------Cancel Logo display
"DFLT" ------------------------- Select Logo of Factory Default
"USER" ------------------------ Select User
%2
"UP" ---------------------------- Select functions to choose forward
"DN" ---------------------------- Select functions to choose backward
Set Logo mode.(Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Set Logo PIN code in %1.
When Logo Lock is enabled:
PIN code is matched ------------------------- Command is valid (Acceptable)
PIN code is mismatched-------------------- Command is invalid (Error code "102")
PIN code is beyond %1 available range -------Command is invalid (Error code"?")
Details
When Logo Lock is disabled:
PIN code is within %1 available range ------- Command is valid (Acceptable)
PIN code is out of %1 available range ------- Command is invalid (Error code "?")
Note: When Logo Lock is enabled, matching Logo PIN code switches Logo but
Logo Lock is not cancelled (Lock status is kept).
*When ÿ
Capture non-practice.
Acceptable
Response
Unacceptable

8.10.7 CF_PIP Command

Command
"CF_PIP_%1" [CR]
"OFF" -------------------- Select Off
"USER1" ---------------- Select User1
"USER2" ---------------- Select User2
%1
"USER3" ---------------- Select User3
"USER4" ---------------- Select User4
"USER5" ---------------- Select User5
Set "Picture in Picture" status.(Available only in the normal Power ON status)
Details
The status set by this command is stored in EEPROM and the setting remains
even after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable

8.10.8 CF_PIPMODE Command

Command
"CF_PIPMODE_%1" [CR]
"PINP" -------------------- Select P in P mode
%1
"PBYP" ------------------- Select P by P mode
Details
Set mode in "Picture in Picture". (Available only in the normal Power ON status)
Acceptable
Response
Unacceptable
(OFF → DFLT → USER → OFF → --)
(OFF → USER → DFLT → OFF → --)
2="USER" is received, error code "101" is returned, in the case of
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
42/88