3. Adjustment of Presser Foot Height
1. Turn the power switch off.
2. Select the needle bar No. 1.
3. Loosen the screw w of the presser foot q, and adjust the presser foot q until it comes
above the cloth top surface when it is at the alignment position (where the pulley B indication
mark " " and the cover indication mark " " are aligned).
Note) When the presser feet have been adjusted in height, check that each needle lowers to the center of the
presser foot hole.
4. Turn on the power switch and lower presser foot q with the lever.