Brother BES-1216AC Instruction Manual page 150

Electronic
Hide thumbs Also See for BES-1216AC:
Table of Contents

Advertisement

Chapter 10 Troubleshooting
Symptom
The main shaft motor lock error oc-
curs.
ERROR A8 frequently occurs.
Wiper out error occurs.
Main shaft rotation speed error oc-
curs.
Exhaust fan motor stops.
148
• Enter the encoder signal mode and manually turn the main shaft pulley.
If it is abnormally heavy, the main shaft mechanism is faulty.
• Does the main shaft motor rotate at all when the error occurs?
If it does not rotate at all, check fuse F1 and F5 on the power supply
PCB in the control box. Refer to the block diagram showing the cable
connections and check to see if connection from the main shaft motor
to the main PCB is proper. Also check connection of connectors P15
and P16 of the main PCB and connectors P1 and P2 on the power
PCB in the box, and connection from connector P14 of the main PCB
to the 14v terminal of the power transformer.
• Manually turn the main shaft pulley in the encoder signal test mode
and check to see if the stop position signal and encoder signal are
proper.
If either of the signals does not change, refer to the block diagram
showing the cable connections and check to see if connection from the
encoder and stop position sensor to the main PCB is proper.
• In the encoder signal test mode, manually turn the main shaft pulley
and check to see that the stop position signal is correct.
If the signal does not change, refer to the cable connection block
diagram and check to see if connection from the stop position sensor
to the main PCB is proper.
• Does the wiper remain projected?
If the wiper is tangled with a thread, remove it. If the wiper does not
return smoothly, adjust it.
• Enter the solenoid test mode and operate the wiper solenoid. Check
the icon on the panel.
If the panel is not changed, check to see if connection from the
wiper sensor to the head PCB is proper. Replace the wiper sensor
with a new one. Replace the head PCB with a new one.
• Enter the encoder signal test mode and manually turn the main shaft
pulley.
If it is abnormally heavy, the main shaft mechanism is faulty.
• Refer to the block diagram showing the cable connections and check
to see if connection from the main shaft motor to the main PCB is
proper. Also check the connection from connectors P14 of the main
PCB to the 14v terminal of the power transformer.
• Refer to the block diagram showing the cable connections and check
to see if connection of connector P22 of the main PCB in the control
box is proper.
• Check fuse F3 on the power supply PCB.
If it is blown, replace it with a new one. If it becomes blown again,
the 24v system circuit is faulty.
BES-916AC • BES-1216AC
Measures

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bes-916ac

Table of Contents