Command bit
S16=
S17=
bit
4-1
5
7,6
S18=
dec hex Function and description
96
60
Profile 3 as active settings
after power on.
128 80 * Factory default as active
settings after power on
dec
hex Test status register.
0
0
No test in progress.
1
1
Loop-back test in progress
3
3
Local Digital Loop-back test
in process.
6
6
Remote Digital Loop-back
test in process.
7
7
Remote Digital Loop-back
with self-test in process.
8
8
Analog Loop-back with self
test in progress.
dec
hex Bit-mapped register.
0-30 0-1E Set leased line transmit
power level from 0 to -15
dBm. (See also S35b3)
(Default *P9).
0
0
Normal dial (Default).
32
20
Reverse dial, go on-line in
answer mode.
0
0
AT Commands set (Default). *I0
64
40
V.25bis command set.
128 80
Dumb mode (no command
accepted).
dec
hex Force modem to fix baud
rate when answering.
0 * 0
Disable fixed baud function.
1-46 1-2E Enable baud rate to be fixed
when answering. Baud rate
Status Registers & Result Codes 95
Ref.
Z3
Z4
+000
&T0
&T1
&T3
&T6
&T7
&T8
+018
*Pn
D
DR
*I1
*I2
+000