Configuring the unit operation settings
Assigning functions to the USER buttons
Functions can be assigned to the eight USER buttons (USER 1 to
USER 8) .
This enables you to operate a desired function by simply pressing a
USER button (USER 1 or USER 8) .
USER buttons (USER 1 to USER 8)
1 .
Press the MENU button .
2 .
Open USER BUTTON menu [35] .
3 .
Turn the F1 dial to display the USER button (USER 1 to
USER 8) you want to set .
4 .
Turn the F2 dial to select a function, and then press the
F2 dial to confirm the selection .
1 .U SER1
30
(continued)
N D 1
Functions that
Operations when USER buttons pressed
can be selected
Pressing a USER button with a function assigned
selects the corresponding ND filter and turns on
the button indicator .
The selected ND filter value differs depending on
the remote camera being controlled .
<Selected ND filter value>
Remote
camera
AW‑HE120
ND1,
AK‑HC1500
ND2,
AK‑HC1800
ND3,
ND4
AW‑HE100
AW‑HE60
AW‑HE50
AW‑HE870
AW‑E860
AW‑E750
AW‑E650
AW‑E350
— : The remote camera setting is not changed
even if a USER button with a function
assigned is pressed .
SWLINK,
Assign these functions when using the function for
BUSCONT,
linking with a switcher .
FASSIST,
⇒ "Setting linking with a switcher" (page 31), "Setting
CAMSEL,
the functions for when the unit is linked with the
CAMINF,
switcher" (pages 32 to 35)
TALLY_IP
Holding down a USER button with the function
assigned turns on the indicator of the button for
POWER OFF
an instant and sends a power‑off request to all the
connected remote cameras .
CAM_PINP DISP,
Assign these settings when an AW‑HE2 HD
CAM_PINP CTL,
integrated camera is connected .
⇒ "Operations of AW‑HE2" (page 51)
CAM_PINP POS
Note
z When executing the function assigned to a USER button, press
z
the SHIFT button to turn off its indicator and then perform the
operation .
When a USER button is pressed while the SHIFT button indicator
is on, either the preset memory group is called or shooting mode
selection of the remote camera is executed .
Functions that can be
assigned
ND1
ND2
ND3
ND4
Through
1/4
1/16
1/64
Clear
1/4
1/16
1/64
—
―
―
―