Operation Check; Initial Seek Operation Check; Operation Test; Diagnostic Test - Fujitsu MBA3073NC - Enterprise 73.5 GB Hard Drive Product Manual

Product manual
Hide thumbs Also See for MBA3073NC - Enterprise 73.5 GB Hard Drive:
Table of Contents

Advertisement

6.3
6.3.1
6.3.2
6.3.3
104
Downloaded from
www.Manualslib.com

Operation Check

Initial seek operation check

If an error is detected during initialization by the initial seek operation check routine at power-on,
the spindle motor of the HDD stops, and then the HDD becomes unusable.
For an explanation of the operation check before the initial seek, refer to the Section 5.6.

Operation test

While the host computer is processing data, the HDD monitors HDD operation including data
processing, command processing, and seek operations. If the HDD detects an error, the HDD
posts the error to the initiator. The initiator then posts the error to the user.
The user may detect an intermittent or nonfatal error such as abnormal noise, abnormal odor, or
very slow operation.
An error posted in an operation test must be investigated. The user can replace the HDD to see
whether the error was caused by the HDD.
Often, errors posted in an operation test may be caused by the host system. Possible causes
include insufficient power capacity, loose cable connection, insufficient timing or insufficient
mechanical play, and problems related to other systems.
If an operation error is detected by the error detection circuit of the HDD, an interrupt occurs.
The interrupt is posted to the MPU on the PCBA. The MPU stops the currently processed
command, and causes the CHECK CONDITION status to post the error to the initiator.
When receiving the CHECK CONDITION status, the initiator issues a REQUEST SENSE
command to collect detailed information about the error. The initiator then issues a REZERO
UNIT command to return the read/write head to track 00. In normal processing, the HDD itself or
initiator determines how to handle the error (processing retry or stop).
To analyze the error posted in the operation test, reconstruct the conditions in which the error
occurred. Then, start troubleshooting the whole host system by replacing the HDD.

Diagnostic test

The diagnostic test is executed to find a faulty subassembly in a faulty HDD, or to check HDD
performance. This test is usually a combination of specific disk drive functions or group of
functions. This test may be executed using a different host computers or test equipment and away
from the environment where the error first occurred.
To analyze the error posted in the diagnostic test, reconstruct the conditions in which the error
occurred. Then, look for a possibly faulty subassembly or part of the HDD.
The procedures to be used in this test depend largely on the type of test equipment used, and are
not covered by this manual.
manuals search engine