Part 2 Master/Slave Layouts And Wiring; Photo-Sensor Installation For Biparting Gate Configuration; Figure 6. Biparting Slide Gate Photo-Sensor Layout - Chamberlain SL 1000-B3 Owner's Manual

Estate series master / slave systems slide, swing, and barrier gate operators
Table of Contents

Advertisement

A. PHOTO-SENSOR INSTALLATION FOR BIPARTING GATE CONFIGURATION
BIPARTING SLIDE GATES
Buy only UL-approved photo-sensors made for use with vehicular gate
operators or system. Otherwise, safe gate operation may be compromised.
IMPORTANT NOTE: The installation shown in Figure 6 above is a suggested layout using emitters
and receivers. Any UL-approved photo-sensors are acceptable, but they must cover the entire area
of gate travel to be effective.
Install photo-sensors in three Coverage Areas as shown in Figure 6.
1. Coverage Area A - Inside-Open Coverage:
Install two photo-sensors: Inside the fence line, from the gate operators to the gate fully open
positions.
2. Coverage Area B - Inside-Closed Coverage:
Install one photo-sensor: Inside the fince line, from the Master gate operator to the Slave gate
operator.
3. Coverage Area C - Outside-Closed Coverage:
Install one photo-sensor: Outside the fence line, from one fence edge to the other.
4. Connect the photo-sensors to whichever unit is most convenient. For wiring instructions,
see Section C, Connecting Input Wiring, below.
Rev E
MASTER/SLAVE LAYOUTS AND WIRING

Figure 6. Biparting Slide Gate Photo-Sensor Layout.

PART 2
WARNING
Doc 01-20201
10 of 33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sw 2000-b3Bg 3000-b3

Table of Contents