Master/Slave Installation Details; Figure 2. Typical Bi-Parting Gate Installation - Chamberlain SL 1000-B3 Owner's Manual

Estate series master / slave systems slide, swing, and barrier gate operators
Table of Contents

Advertisement

C. MASTER/SLAVE INSTALLATION DETAILS
1.
BI-PARTING GATE DETAILS
The simple Bi-Parting Gate is typically used in low traffic residential sites due to its ease of use. The Bi-
Parting configuration can consist of any combination of models SL 1000-B3 (slide gate),
SW 2000-B3 (swing gate), and BG 3000-B3 (barrier gate).
Fence
Connect MagLock to one unit only.
HOW IT WORKS:
The gates in a Bi-Parting configuration are mirror images of each other and act identically.
A Fault in one unit affects both units (see Troubleshooting/Maintenance for Fault List in the
Installation and Operation manual for the individual gate).
A Continuous open input in either unit opens the gates and holds them open.
There are 3 different ways to close the gates (entering or exiting):
1.
Reclose Timer: When the Reclose Timer expires, gates close automatically.
2.
ATG (Anti-Tailgate) and Interrupt Loop: With ATG ON, clearing the Inside Interrupt Loop closes the
gates. NOTE: For safety reasons, ATG does not function with gate type SWING or LINEAR.
3.
Alternate Action: With ATG and TIMER OFF, a Radio or CYCLE command will close fully-open
gates.
INPUT CONNECTIONS: Refer to Part 2, Master/Slave Layout and Wiring, for more details.
Inputs can be connected to either gate.
Rev E
ADDITIONAL
INPUTS:
Radio
Cycle
Interrupt Bar
Photo-Sensors
Fire
MagLock
Manual Inputs
Gate
Operator
Master
Master Gate

Figure 2. Typical Bi-Parting Gate Installation.

COMPLEX
Exit Loop
Inside Interrupt
Loop
Shadow Loop
(swing gates only)
Master/Slave Cable
Slave Gate
Outside Interrupt
Loop
STREET
Doc 01-20201
Gate
Operator
Slave
Fence
1384F2
4 of 33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sw 2000-b3Bg 3000-b3

Table of Contents