Chamberlain Elite SL3000UL Owner's Manual

Chamberlain Elite SL3000UL Owner's Manual

Vehicular slide gate operator
Hide thumbs Also See for Elite SL3000UL:

Advertisement

O W N E R ' S M A N U A L
S L 3 0 0 0 U L ™
V E H I C U L A R S L I D E G AT E O P E R AT O R
THE SL3000UL™ IS FOR USE ON VEHICULAR PASSAGE GATES ONLY
AND NOT INTENDED FOR USE ON PEDESTRIAN PASSAGE GATES.
UL325
UL991
compliant
compliant

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Elite SL3000UL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Chamberlain Elite SL3000UL

  • Page 1 O W N E R ’ S M A N U A L S L 3 0 0 0 U L ™ V E H I C U L A R S L I D E G AT E O P E R AT O R THE SL3000UL™...
  • Page 3: Table Of Contents

    TA B L E O F C O N T E N T S SPECIFICATIONS AND WARNINGS WARNING Overview and Specifications ......2 Mechanical Model Classification .
  • Page 4: Overview And Specifications

    Specifications and Warnings S L 3 0 0 0 U L ™ M O D E L S O V E R V I E W S i n g l e M o t o r M o d e l s SL3000UL™...
  • Page 5: Model Classification

    U L 3 2 5 M O D E L C L A S S I F I C A T I O N S The SL3000UL™ is intended for use in vehicular slide gate applications: Class I – Residential vehicular gate operator A vehicular gate operator (or system) intended for use in a home of one-to four single family dwellings, or a garage or parking area associated therewith.
  • Page 6: Safety Installation Information

    S A F E T Y I N S T A L L A T I O N I N F O R M A T I O N 1. Vehicular gate systems provide convenience and security. Gate systems are comprised of many component parts. The gate operator is only one component.
  • Page 7: Safety Precautions

    S A F E T Y P R E C A U T I O N S THE SL3000UL™ IS FOR USE ON VEHICULAR PASSAGE GATES ONLY AND NOT INTENDED FOR USE ON PEDESTRIAN PASSAGE GATES. WARNING To prevent SERIOUS INJURY or DEATH from a moving gate: •...
  • Page 8: Suggested Safety Protection Device Locations

    S U G G E S T E D S A F E T Y P R O T E C T I O N D E V I C E L O C AT I O N S WARNING To prevent SERIOUS INJURY or DEATH from a moving gate: •...
  • Page 9 S U G G E S T E D S A F E T Y P R O T E C T I O N D E V I C E L O C AT I O N S WARNING To prevent SERIOUS INJURY or DEATH from a moving gate: •...
  • Page 10: Installation

    Installation I N S TA L L AT I O N S E T U P S F r o n t o r R e a r P o s i t i o n w i t h S i n g l e O p e r a t o r UL approved catch roller with safety cover.
  • Page 11: Safety Catch Rollers And Gate Rail Stops

    S A F E T Y C AT C H R O L L E R S A N D G AT E R A I L S T O P S Safety Catch Rollers DO NOT use a Gate Catch Post. Because the coasting distance may vary due to changes in temperature, it is...
  • Page 12: Mounting Operator

    M O U N T I N G O P E R AT O R Top Inside View Conduit area without battery back-up. 8.25" 4 Concrete Anchors 13" 1/2" x 3 1/2" High voltage Above conduit. 6" Ground 10" Low voltage conduit.
  • Page 13: Chain Installation

    C H A I N I N S TA L L AT I O N T Y P E S Drawings not to scale Front Operator Position Weld rear WARNING bracket with gate To reduce the risk of SERIOUS INJURY or DEATH, make sure in closed exposed idler pulleys have safety covers on them.
  • Page 14: Control Board Description

    C O N T R O L B O A R D D E S C R I P T I O N 1 HP Board Plug-In Loop Detectors CENTER SAFETY EXIT Maglock/Solenoid Relay Module Connection UL Alarm Connection Surge Suppressor Master/Second DC BACKUP Connection...
  • Page 15: Surge Suppressor Terminal Connections

    Master/Second Connection S U R G E S U P P R E S S O R T E R M I N A L C O N N E C T I O N S Output Power Ground 24 VDC 120 Vac Power Removable...
  • Page 16: Wiring

    Wiring WARNING To reduce the risk of SEVERE INJURY or DEATH: • DO NOT install any wiring or attempt to run the operator • ANY maintenance to the operator or in the area near the without consulting the wiring diagram. We recommend that operator MUST not be performed until disconnecting the you Install an optional reversing edge BEFORE proceeding electrical power and locking-out the power.
  • Page 17: Vac Power Connection

    1 2 0 V a c P O W E R C O N N E C T I O N On-Off switch for operator. Black 120 Vac White Neutral Green Ground Use a 20 amp dedicated circuit for each operator. Green Ground Input power 120 Vac, 60 Hz.
  • Page 18: Linking Master/Second Operators

    L I N K I N G M A S T E R / S E C O N D O P E R A T O R S Use a 20 amp dedicated power circuit for each operator. Never run high voltage and low voltage wires in same conduit. Run low voltage 16-18 gauge wire in UL approved conduit to link operators together.
  • Page 19: Solenoid/Maglock Connection

    S O L E N O I D / M A G L O C K R E L A Y C O N N E C T I O N Connection of a solenoid or magnetic lock can be made using the J7 board connector and “Optional” Relay Adapter Module. See Accessories.
  • Page 20: Dc2000™ Connection

    F A C T O R Y I N S T A L L E D D C 2 0 0 0 ™ C O N N E C T I O N D C 2 0 0 0 ™ S t a r t u p Plug in the 12 pin plug into the DC2000™...
  • Page 21 D C 2 0 0 0 ™ D E V I C E W I R I N G M a n u a l l y O p e r a t e d D C 2 0 0 0 ™ D e v i c e s Manual external devices should be dry-contact which do not consume any current like push buttons or a key switch.
  • Page 22: Plug-In Loop Detector Wiring

    P L U G - I N L O O P D E T E C T O R W I R I N G Plug-In Loop Detectors See Accessories CENTER SAFETY EXIT POWER ON DETECT LOOP FAIL FREQUENCY SENSITIV TY BOOST ™...
  • Page 23: Vac External Loop Detector Wiring

    1 2 0 V a c E X T E R N A L L O O P D E T E C T O R W I R I N G ® Class 2 Class 2 Supply Supply Center Center S fet S fet...
  • Page 24: Entrapment Protection Devices (Contact Sensors)

    E N T R A P M E N T P R O T E C T I O N D E V I C E S Contact Sensors (Edge Sensor) WARNING To prevent SERIOUS INJURY or DEATH from a moving gate: •...
  • Page 25: Entrapment Protection Devices (Non-Contact Sensors)

    E N T R A P M E N T P R O T E C T I O N D E V I C E S Non-Contact Sensors (24 VDC Photo Electric Sensors) NOTE: Property owners are obligated to test photo sensors monthly. Entrapment Non-Contact Sensor Outside Property Entrapment Danger...
  • Page 26: Omni Option Board Connections (Optional)

    O M N I O P T I O N B O A R D C O N N E C T I O N S Purchased separately from Chamberlain Elite. See Accessories. NOTE: Refer to the Omni Option Board manual for more specific information.
  • Page 27: Adjustments

    Adjustments WARNING To reduce the risk of SERIOUS INJURY or DEATH: disconnect electric power BEFORE performing ANY adjustments. S E T G A T E O P E N I N G D I R E C T I O N CENTER SAFETY EXIT...
  • Page 28: Radio Receiver Programming

    3 1 5 M H Z 2 4 V D C R A D I O R E C E I V E R P R O G R A M M I N G Setting Security Mode (High) or (Normal): WARNING The receiver is factory set at HIGH security mode.
  • Page 29 3 1 5 M H Z 2 4 V D C R A D I O R E C E I V E R P R O G R A M M I N G IMPORTANT: Hand Held Remote NOT Included. NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery.
  • Page 30: Setting The Timer (On, Off)

    S E T T I N G T I M E R ( O N , O F F ) S i n g l e O p e r a t o r To use the automatic close for the gate system the timer switch should be put in the “ON”...
  • Page 31: Adjusting Reversing Sensor(S)

    A D J U S T I N G R E V E R S I N G S E N S O R ( S ) Adjust the “Reverse Sensor” on the control board. Alarm Sensor does not need to be adjusted except where noted below. The level of reverse sensitivity depends on the weight of the gate and the condition of installation.
  • Page 32: Maintenance

    9. ALL maintenance MUST be performed by a Failure to adjust and retest the gate operator properly Chamberlain Elite professional. can increase the risk of INJURY or DEATH. SAVE THESE INSTRUCTIONS.
  • Page 33: Built-In Reset Switch

    B U I L T - I N R E S E T S W I T C H When the gate operator’s audio alarm has been tripped (see below), the reset switch must be pushed for the operator to function again. The reset switch will shut off an activated audio alarm and reset the operator to function again.
  • Page 34: Emergency Manual Release

    E M E R G E N C Y M A N U A L R E L E A S E T u r n t h e p o w e r O F F ! NOTE: Use the dedicated breaker switch to disconnect power to the operator.
  • Page 35: Accessories

    Magnetic Lock (Outdoor) Part # AELD ODC2000SL Part # MG1300 Remote Controls For more information about accessories: Relay Adapter Module www.chamberlain.com Part # Q400MAU Quick Close Circuit (QCC) 3-Button Control Station Part # OQCCOMNI Part # 02-103 Omni Option Board...
  • Page 36: Wiring Diagrams

    W I R I N G D I A G R A M • S L 3 0 0 0 U L ™ Electronic Power Strip White Wires Black Wires Chassis Ground OmniControl™ Board CENTER SAFETY EXIT Motor Relay Adapter Module (Optional) 1234567...
  • Page 37 W I R I N G T A B L E • S L 3 0 0 0 U L ™ OmniControl™ Board Signal Type Direction Level (+/- 10%) Input Connection J Pin # Safety Loop 5 or 0 VDC External Loop Input Power Neutral Detector Wires,...
  • Page 38 W I R I N G D I A G R A M • S L 3 0 0 0 U L D M ™ Electronic Power Strip White Wires Black Wires Chassis Ground OmniControl™ Board Motor Motor CENTER SAFETY EXIT Relay Adapter...
  • Page 39 W I R I N G T A B L E • S L 3 0 0 0 U L D M ™ OmniControl™ Board J Pin # Signal Type Direction Level (+/- 10%) Input Connection Safety Loop 5 or 0 VDC External Loop Input Power Neutral Detector Wires,...
  • Page 40 W I R I N G D I A G R A M • S L 3 0 0 0 U L 1 H P ™ Electronic Power Strip White Wires Black Wires Chassis Ground 1 HP Board OmniControl™ Board Motor Black White...
  • Page 41 W I R I N G T A B L E • S L 3 0 0 0 U L 1 H P ™ OmniControl™ Board J Pin # Signal Type Direction Level (+/- 10%) Input Connection 5 or 0 VDC Safety Loop External Loop Detector Input Power Neutral...
  • Page 42 W I R I N G D I A G R A M • D C 2 0 0 0 ™ F O R S I N G L E A N D D M NOTE: This diagram only shows the DC2000™...
  • Page 43 W I R I N G T A B L E • D C 2 0 0 0 ™ NOTE: All devices wired to the DC2000™ MUST be dedicated to it alone. Normal operation will be controlled by separate devices wired to the OmniControl™...
  • Page 44: Troubleshooting

    Troubleshooting The Gate Will Not Operate with Remote: EN LEFT OPEN RIGH RADIO STRIKE GATE OPEN LOCKED OPEN LEFT PEN RIGH RECEIVER RADIO CENTER STRIKE GATE LOOP OPEN LOCKED RECEIVER The radio receiver LED on the control board remains “OFF” when using the remote control. CENTER LOOP The radio receiver LED on the...
  • Page 45 T R O U B L E S H O O T I N G C O N T I N U E D Condition Probable Causes Solution 1. Short circuit at terminals 11 and 13. 1. Remove the short circuit condition at the Overload LED ON 2.
  • Page 46: Repair Parts

    Repair Parts R E P A I R P A R T I L L U S T R A T I O N S SL DM *Q029 ODC2000SL Q033 Q254 Q024 Q028 K75-50932 312HM DM / 1 HP Q039 K75-50893 Q027 Q030...
  • Page 47: How To Order Repair Parts

    • PART NUMBER • PART NAME • MODEL NUMBER Address orders to: THE CHAMBERLAIN GROUP, INC. Technical Support Group 6020 S. Country Club Road Tucson, Arizona 85706 R E P A I R P A R T N A M E S A N D N U M B E R S AH110 - Chain no.
  • Page 48 System Diagram...
  • Page 49: Installation Checklist

    Installation Checklist 1. Owner and Installer must read all warnings and safety precautions. 2. Make sure concrete mounting pad is big enough and deep enough for operator. 3. Operator must be securely fastened to concrete pad. 4. Operator chain must be 4 inch Minimum from gate. Chain must not be too tight or too loose. 5.
  • Page 50: Warranty Policy

    7 YEAR RESIDENTIAL/ 5 YEAR COMMERCIAL SL3000UL™ LIMITED WARRANTY The Chamberlain Group, Inc. (“Seller”) warrants to the first retail purchaser of this product, for the structure in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of 7 year residential/ 5 year commercial from the date of purchase [and that the SL3000UL™...
  • Page 52 S L 3 0 0 0 U L ™ UL325 UL991 compliant compliant 845 Larch Avenue Elmhurst, Illinois 60126-1196 © 2008, The Chamberlain Group, Inc. – All Rights Reserved 01-50388E...

Table of Contents

Save PDF