SL400EVK / SL600EVK / SL1000EVK

Advertisement

Table of Contents
loading

Summary of Contents for Chamberlain SL400EVK

  • Page 1 SL400EVK / SL600EVK / SL1000EVK Sliding Gate Operator Installation Manual* Manuel d‘installation de l‘opérateur de portail coulissant Installatiehandleiding schuifhekaandrijving Installationshandbuch für Schiebetorantriebe Instrukcja instalacji operatora bramy przesuwnej Návod k instalaci pohonu posuvné brány Návod na inštaláciu pohonu posuvnej brány Priročnik za namestitev upravljalnika drsnih vrat Csúszókapu kezelő...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS NOTE: The original installation and operating instructions were compiled in English. Any other available language is a translation of the original English version. 1. SAFETY INSTRUCTIONS AND INTENDED USE......................................2 2. DELIVERY SCOPE..............................................4 3. TOOLS NEEDED.................................................4 4. OVERVIEW OF GATE OPERATOR..........................................4 5.
  • Page 3: Safety Instructions And Intended Use

    1. SAFETY INSTRUCTIONS AND INTENDED USE About this Manual – Original Manual These instructions are the original operating instructions according the machinery directive 2006/42 EC. The instruction manual must be read carefully to understand important product information. Pay attention to the safety and warning notices. Keep the manual in safe place for future reference and to make it available to all persons for inspection, service, maintenance and repair.
  • Page 4 1. SAFETY INSTRUCTIONS AND INTENDED USE During operation, the gate should not under any circumstances obstruct public path ways and roads (public area). When using tools and small parts to install or carry out repair work on a gate exercise caution and do not wear rings, watches or loose clothing. To avoid serious personal injury due to entrapments, remove any locking device fitted to the gate in order to prevent damage to the gate.
  • Page 5: Delivery Scope

    2. DELIVERY SCOPE SL400EVK / SL600EVK / SL1000EVK Remote Release Key Installation Control (2x) (2x) Manual Motor unit with control board 3. TOOLS NEEDED 8, 13 mm 8, 13 mm 4. OVERVIEW OF GATE OPERATOR 1. Motor with control board 2.
  • Page 6: Mechanical Installation

    Herewith you start mechanical installation of the gate operator. 5.1 Dimensions of Gate and Operator SL400EVK, SL600EVK, SL1000EVK General information and conditions for set-up. Before installing the gate operator ensure that the gate is running smoothly. The weight of the door is not allowed to be completely placed on the motor shaft.Ensure that all the required cables (power cable, accessory cables etc) are prepared and laid correctly before the base plate is installed in the concrete.
  • Page 7: Installing Motor On The Base Plate

    5. MECHANICAL INSTALLATION 5.4 Installing Motor on the Base Plate 1. Once the base plate is fixed, raise the nut securing the base plate from the top about 5-10 mm and add a washer. 2. Remove the small front plastic cover from the operator and make a manual release by putting the key into keyhole, turning right and pulling the lever down (see manu- al release page 5).
  • Page 8: Limit Switch Position Set Up

    5. MECHANICAL INSTALLATION 5.7 Limit Switch Position Set Up 1. Ensure the operator is powered. 2. Position the brackets with magnets on the left and right ends of the rack where the end positions are assumed. The magnets are marked with L for left side and R for right side and shall be positioned on the right or on the left from operator (see picture 12).
  • Page 9: Wiring Diagram

    6. WIRING DIAGRAM AC 230V IN IR 3 IR 3 IR 2 IR 2 IR 1 IR 1 EXAMPLE 8.2K BATTERY Secondary Control Board 24V BAT EDGE IR SENSOR COMMAND E-LK SPEC 24VDC SYNC SE SE GND IR2 IR1 IN3 IN2 IN1 24V external accessories Examples: external receiver EXAMPLE...
  • Page 10: Programming

    7. PROGRAMMING 7.1 Display, Programming Buttons and Function Setting 2 digit LED display Programming buttons function (4 buttons): Button Function program / delete remote controls and specific functions enter programming mode, select function and save LED spot Navigate through the menu and change the value on display Function and programmed values are shown on LED display.
  • Page 11: Wing Movement Direction

    7. PROGRAMMING 7.3 Wing Movement Direction Before programming, move the gate manually in the middle position and re-engage release mechanism (see page 6). Press and hold the “–“ button on the control board and ensure that the motor is moving in CLOSE direction. If correct, immedia- tely let go of the “-“...
  • Page 12: Stand-By Mode

    7. PROGRAMMING Advanced Learning Mode (manual setting of Soft Stop position) Advanced Learning Mode (manual setting of Soft Stop) 1. Open LL Menu. 2. Press and hold “+ and –“ buttons for 2 seconds. Automatic learning starts, LL will flash on the display during the complete process. 3.
  • Page 13: Programming And Erasing Of Remote Controls, Radio Accessories And Myq Devices

    7. PROGRAMMING 7.6 Programming and Erasing of Remote Controls, Radio Accessories and myQ Devices Program remote control devices (transmitters and wireless wall controls): NOTE: the remote controls delivered with the operator are already factory pre- learned to the operator (top button near the LED) and do not require extra pro- gramming.
  • Page 14: Advanced Settings

    7. PROGRAMMING 7.7 Advanced Settings Herewith you start with Advanced Settings. 7.7.1 Overview Advanced Settings Function Function Transmitter Flashing Light IR1 photocell Pre-Flashing IR2 photocell Special contact IR3 photocell START Speed in OPEN and CLOSE Input 1 command Maintenance counter Password (This menu is only available after the Input 2 command Learning phase was finished.)
  • Page 15: Partial Opening

    7. PROGRAMMING 7.7.7 Reversal Time after Impact Open – Close – Open Reversal time after impact function defines reversal behaviour after obstacle obst- Open – Stop – Close – Stop – Open (Default) ruction during closing or opening movement. This reversal behaviour is valid both for motor force detection and safety edge application.
  • Page 16: Start Speed In Open And Close Directions

    7. PROGRAMMING 7.7.11 Start Speed in Open and Close Directions 7.7.12 Maintenance Counter Start Speed function allows switching the Soft-Start in OPEN and CLOSE directi- Maintenance Counter function allows to set maintenance interval in cycles. ons ON and OFF. 4 seconds pre-flashing of the Flashing Lamp will be a signal the interval is reached. If PF Function (Pre-Flashing) is active then 4 second pre-flashing will be added to the set time.
  • Page 17: Password Change

    7. PROGRAMMING 7.7.13c Password Change 1. Choose “PS” function and press “P” button. 2. “00” flashes in display. 3. Use “+” or “–” buttons to enter current password and press “S” button. Value starts flashing. 4. Use “+” or “–” buttons to enter NEW password and press “P” button. 5.
  • Page 18: Battery Backup

    8. BATTERY BACKUP Battery Back-Up Mode (BBU) Optional 12V, 2.2Ah lead batteries SKU 490EV (optional, not included) can be mounted inside operator housing. Follow the manual of SKU Nr 490EV for exact installation procedure. A Flashing lamp (if mounted) will flash 2 seconds every 10 minutes indicating BBU mode and power loss.Control board will switch into stand-by mode with active radio receiver accepting radio control device commands only.
  • Page 19: Technical Data

    10. TECHNICAL DATA SL400EVK SL600EVK SL1000EVK Input Voltage 220-240 Input frequency 50/60 Motor Voltage "Standby consumption 4.45 (without accessories)" Rated Power Rated Load Cycles per hour Max. cyles per day Max. gate weight 1000 Max. gate width Max. opening speed...
  • Page 20: Maintenance

    The manual consists of these operating instructions and the declaration of conformity. The radio equipment type (TX4EVF) is in compliance with Directive 2014/53/EU and for UK with Radio Equipment Regulation SI 2017 No. 1209. The full text of the EU declaration of conformity is available at the following internet address: https://doc.chamberlain.de...
  • Page 21 Chamberlain GmbH Saar-Lor-Lux-Str. 19 66115 Saarbrücken Germany WEEE-Reg.Nr. DE66256568 www.liftmaster.eu info@liftmaster.eu 114A5443 2021, all rights reserved...