Power Distribution Devices - HP BL20p - ProLiant - G2 Setup And Installation Manual

Hp proliant bl p-class system setup and installation guide
Hide thumbs Also See for BL20p - ProLiant - G2:
Table of Contents

Advertisement

Power Distribution Devices

Table E-5: Operating and Performance Specifications for Power Distribution Devices
Power enclosures or
facility DC feeds
supported
(3U each)
Server blade
enclosures supported
(6U each)
Total rack height of
supported enclosures
Dimensions
Height
Depth
Width
Weight
Rated operating
voltage
Max total power
supported
HP ProLiant BL p-Class System Setup and Installation Guide
Power Bus Box
1
1
9U
12.95 cm (5.1 in)
8.26 cm (3.25 in)
9.14 cm (3.6 in) each
1.64 kg (3.62 lb)
-43.2 VDC to -54 VDC
3,000 W
Mini Bus Bar
1
3
21U
49.40 cm (19.45 in)
5.59 cm (2.2 in)
50.14 cm (19.74 in)
59.9 kg (13.2 lb)
-43.2 VDC to -54 VDC
9,000 W
Specifications
Scalable Bus Bar
2
5
36U
123.37 cm (48.57 in)
5.59 cm (2.2 in)
50.14 cm (19.74 in)
11.79 kg (26 lb)
-43.2 VDC to -54 VDC
15,000 W
continued
E-9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proliant bl p-class

Table of Contents