HP BL20p - ProLiant - G2 Setup And Installation Manual page 100

Hp proliant bl p-class system setup and installation guide
Hide thumbs Also See for BL20p - ProLiant - G2:
Table of Contents

Advertisement

Specifications
Table E-1: Operating and Performance Specifications for the Server
Blade Enclosure
Rated input power
Individual server blade
bay ratings
Rated input voltage
Rated input current
Rated input power
Temperature range
Operating
Non-operating
Relative humidity,
noncondensing
Operating
Non-operating
Wet bulb temperature
Operating
Non-operating
2
Operating temperature has an altitude derating of 1°C (33.8°F) per 304.8 m
(1,000 ft). No direct sunlight. Upper operating limit is 3,048 m (10,000 ft) or
70 Kpa/10.1 psia. Upper non-operating limit is 9,144 m (30,000 ft) or
30.3 KPa/4.4 psia.
3
Storage maximum humidity of 95% is based on a maximum temperature of
45°C (113°F). Altitude maximum for storage is 70 KPa.
E-2
continued
3,000 W
-43 VDC to -53 VDC
6.25 A at -48 VDC
300 W
2
10° to 35°C
-30° to 60°C
3
20% to 80%
5% to 95%
28°C
38.7°C
HP ProLiant BL p-Class System Setup and Installation Guide
Nominal -48 VDC
(50° to 95°F)
(-22° to 140°F)
(82.4°F)
(101.7°F)