Configuring Snmp Alert Settings; Configuring Serial Port Settings - Lenovo RD220 - ThinkServer - 3798 User Manual

Integrated management module user guide
Hide thumbs Also See for RD220 - ThinkServer - 3798:
Table of Contents

Advertisement

3. Scroll to the bottom of the page and click Save.

Configuring SNMP alert settings

The SNMP agent notifies the IMM about events through SNMP traps. You can
configure the SNMP to filter the events based on the event type. Event categories
that are available for filtering are Critical, Warning and System. The SNMP alert
settings are global for all SNMP traps.
Notes:
1. The IMM provides two Management Information Base (MIB) files for use with
2. IMM supports the SNMPv1 and SNMPv3 standards.
Complete the following steps to select the type or types of alerts that are sent to
SNMP:
1. Log in to the IMM on which you want to set remote alert attempts. For more
2. In the navigation pane, click Alerts and scroll down to the SNMP Alerts
3. Select the type or types of alerts. The remote alerts are categorized by the
4. Scroll to the bottom of the page and click Save.

Configuring serial port settings

The IMM provides two serial ports that are used for serial redirection.
Serial port 1 (COM1) is used for IPMI Serial over LAN (SOL). COM1 is
configurable only through the IPMI interface.
COM2 is used for serial redirection through Telnet or SSH. COM2 is not
configurable through the IPMI interface. On rack-mounted and tower servers,
COM2 is an internal COM port with no external access.
Both serial ports use 8 data bits, null parity, and 1 stop bit. A baud rate choice of
9600, 19200, 38400, 57600, 115200, and 230400 is available.
You can configure the serial redirection and command-line interface for the COM2
port in the IMM.
26
Integrated Management Module: User Guide
Delay between entries
Use the Delay between entries field to specify the time interval (in
minutes) that the IMM waits before sending an alert to the next
recipient in the list.
Delay between retries
Use the Delay between retries field to specify the time interval (in
minutes) that the IMM waits between retries to send an alert to a
recipient.
SNMP applications. The MIB files are included in the IMM firmware update
packages.
information, see Chapter 2, "Opening and using the IMM Web interface," on
page 9.
Settings area.
following levels of severity:
v Critical
v Warning
v System

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thinkserver td200Thinkserver td200xThinkserver series

Table of Contents