10. Click Advanced Ethernet Setup if you need to set additional Ethernet
11. Modify the advanced Ethernet settings as necessary.
12. Scroll to the bottom of the page and click Save.
13. Click Cancel to return to the Network Interfaces page. If DHCP is enabled,
14. If DHCP is enabled, to view the DHCP server assigned setting, click IP
30
Integrated Management Module: User Guide
8. In the Gateway address field, type your network gateway router. The gateway
address must contain four integers from 0 - 255 with no spaces or consecutive
periods and separated by periods.
9. Scroll to the bottom of the page and click Save.
settings.
The following table describes the functions on the Advanced Ethernet Setup
page.
Table 4. Functions on the Advanced Ethernet Setup page
Field
Function
Auto Negotiate
The IMM determines the data rate and duplex settings automatically,
according to your switch capabilities.
Data rate
Use the Data Rate field to specify the amount of data that is to be
transferred per second over your LAN connection. To set the data rate,
click the menu and select the data-transfer rate, in Mb
to the capability of your network. To automatically detect the
data-transfer rate, set the Auto Negotiate field to Yes, which is the
default value.
Duplex
Use the Duplex field to specify the type of communication channel that
is used in your network.
To set the duplex mode, select one of the following choices:
v Full enables data to be carried in both directions at once.
v Half enables data to be carried in either one direction or the other, but
not both at the same time.
To automatically detect the duplex type, set the Auto Negotiate field to
Yes, which is the default value.
Maximum
Use the Maximum transmission unit field to specify the maximum size
transmission
of a packet (in bytes) for your network interface. For Ethernet, the valid
unit
maximum transmission unit (MTU) range is 60 - 1500. The default value
for this field is 1500.
Locally
Enter a physical address for the IMM in the Locally administered MAC
administered
address field. If a value is specified, the locally administered address
MAC address
overrides the burned-in MAC address. The locally administered address
must be a hexadecimal value from 000000000000 through FFFFFFFFFFFF.
This value must be in the form xx:xx:xx:xx:xx:xx where x is a number 0 -
9. The IMM does not support the use of a multicast address. The first
byte of a multicast address is an odd number (the least significant bit is
set to 1). Therefore, the first byte must be an even number.
Burned-in MAC
The burned-in MAC address is a unique physical address that is
address
assigned to this IMM by the manufacturer. The address is a read-only
field.
1
Mb equals approximately 1 000 000 bits.
the server automatically assigns the host name, IP address, gateway address,
subnet mask, domain name, DHCP server IP address, and up to three DNS
server IP addresses.
Configuration Assigned by DHCP Server.
1
, that corresponds