Table of Contents

Advertisement

2000 Series | Program Entry Guide | 6.0
Open/Close
EN | 25
6.2

Exit

Exit
If you enable the
feature, pressing the [CLEAR]
key at the keypad when the system is On with No
Delay starts exit delay. The system sounds the exit
Exit Tone
delay tone (if
is programmed Yes) and
bypasses all points programmed for exit delay (Digit 1
of point code is 6 or 8). The rest of the system
remains On with No Delay. The tone and bypass
remain until exit delay expires. The system returns to
On with No Delay
the
state. The Exit feature allows
one user to exit a system that is On with No Delay,
leaving those left inside fully protected.
If the user presses [CLEAR] during the exit delay, the
system returns to On with No Delay.
A faulted point (open door) at the end of exit delay
creates an Exit Error alarm.
If an alarm occurs within 2 minutes of the end of exit
delay, the system sends an Alarm Recent Close
Report.
All Exit: Only allows users access to the Exit feature
when the system is All On with No Delay (instant).
Part Exit: Only allows users access to the Exit feature
when the system is Part On with No Delay (instant).
All & Part Exit: Allows users access to the Exit feature
when either All or Part of the system is All On with
No Delay (instant) or Part On with No Delay (instant).
Bosch Security Systems | 7/05 | 35114F

Advertisement

Table of Contents
loading

Table of Contents