2000 Series | Program Entry Guide | 13.0
Table 18: continued
Programmers
A,B,C Key,
Momentary
Off with Passcode
Follow Alarm Output
All On
Part On
Reset
AC Failure
Battery Trouble
Communication Fail
Communicating
Ground Start
Entry and Exit Delay
Extended Delay
Pulsed Output
Bosch Security Systems | 7/05 | 35114F
Keypad
Description
8
Activates the relay output when a user presses a selected function key. The relay
output activates for 10 seconds. Do not program both relays for this function,
doing so might cause inconsistent relay operation.
Select the function keys to monitor at the Parameter prompt.
9
Activates the relay for 10 seconds when a selected user turns the system off with
a passcode.
Note:
Do not program both relays for this function, doing so can cause inconsistent relay
operation.
Select the Users to monitor at the Parameter prompt.
10
Parallels activity at the alarm output (Terminals 4 and 5).
11
Activates the relay at the start of exit delay when the system is All On. The
output remains activated until the system is turned off.
12
Activates the relay at the start of exit delay when the system is Part On. The
output remains activated until the system is turned off.
13
Activates the relay output when a user presses the [3] key to reset the system.
The relay output activates for 4 seconds. Do not program both relays for this
function, doing so might cause inconsistent relay operation.
14
Provides a steady output when the system detects a loss of power at Terminals 1
and 2. The driver remains activated until AC power restores.
15
Provides a steady output when the system detects a low or missing battery
condition. The relay remains activated until the battery restores.
16
Provides a steady output when the system fails to communicate with the receiver
within ten dialing attempts when two phone numbers are programmed, or five
dialing attempts when one phone number is programmed. The relay remains
activated until the system successfully communicates a report to the receiver.
17
Activates the relay output when the system seizes the phone line. The relay
remains activated until the system releases the phone line.
18
Activates the relay output for 900 milliseconds after the system seizes the phone
line. Use this function to generate dial tone on ground start systems.
Note:
Do not program both relays for this function, doing so can cause inconsistent relay
operation.
19
Relay provides a steady output during entry and exit delays.
20
Relay provides a steady output during extended delay.
The relay does not activate if you fault an Extended Delay point before you start
exit delay, or if you bypass the Extended Delay point while you are in exit delay.
21
This function provides a continuous pulsed output.
Do not assign this function to a relay without "anding" it to another function.
Refer to the Relay 1 Logic 1 and Relay 2 Logic 1 prompts in Section 13.1 Relay
Function Logic. For example, "anding" this function to the Alarm function results
in pulsed output for the duration of Bell Time.
The Pulsed Output does not activate when alarms from A, B, C Keys occur.
Relays