Redundant Power System Led - Cisco WS-C2950-24 Configuration Manual

Software configuration guide
Hide thumbs Also See for WS-C2950-24:
Table of Contents

Advertisement

Cluster Manager and VSM

Redundant Power System LED

Note
Table 2-3
Cisco RPS 600 LED on the Catalyst 2900 XL and Catalyst 3500 XL Switches Except the
Catalyst 2912 LRE, 2924-LRE, and 3524-PWR XL Switches
Color
RPS Status
Black (off)
RPS is off or is not installed.
Green
RPS is operational.
Blinking green
RPS and the switch AC power supply are both powered up. If the switch power
supply fails, the switch powers down and after 15 seconds restarts, using power
from the RPS. The switch goes through its normal boot sequence when it restarts.
Note
Amber
RPS is connected but not functioning properly. One of the power supplies in the
RPS could be powered down, or a fan on the RPS could have failed.
Catalyst 2900 Series XL and Catalyst 3500 Series XL Software Configuration Guide
2-8
The Redundant Power System (RPS) LED shows the RPS status.
Table 2-4
list the LED colors and their meanings.
The Catalyst 2912 LRE XL, Catalyst 2924 LRE XL, and
Catalyst 3524-PWR XL switches use the Cisco RPS 300
(model PWR300-AC-RPS-N1). All other Catalyst 2900 XL and
Catalyst 3500 XL switches use the Cisco RPS 600
(model PWR600-AC-RPS). Refer to the appropriate switch documentation for
RPS descriptions specific for the switch.