Configuring Stp Port Priorities And Load Sharing - Cisco WS-C2950-24 Configuration Manual

Software configuration guide
Hide thumbs Also See for WS-C2950-24:
Table of Contents

Advertisement

Load Sharing Using STP

Configuring STP Port Priorities and Load Sharing

Command
Step 1
vlan database
Step 2
vtp domain domain-name
Step 3
vtp server
Step 4
exit
Step 5
show vtp status
Step 6
show vlan
Step 7
configure terminal
Step 8
interface fa0/1
Step 9
switchport mode trunk
Step 10
end
Step 11
show interface fa0/1
switchport
Step 12
Step 13
Step 14
show vlan
Step 15
configure terminal
Catalyst 2900 Series XL and Catalyst 3500 Series XL Software Configuration Guide
8-48
Beginning in privileged EXEC mode, follow these steps to configure the network
shown in
Figure
8-5:
Purpose
On Switch 1, enter VLAN configuration mode.
Configure a VTP administrative domain.
The domain name can be from 1 to 32 characters.
Configure Switch 1 as the VTP server.
Return to privileged EXEC mode.
Verify the VTP configuration on both Switch 1 and
Switch 2.
In the display, check the VTP Operating Mode and the VTP
Domain Name fields.
Verify that the VLANs exist in the database on Switch 1.
Enter global configuration mode.
Enter interface configuration mode, and define Fa0/1 as the
interface to be configured as a trunk.
Configure the port as a trunk port.
The trunk defaults to ISL trunking.
Return to privileged EXEC mode.
Verify the VLAN configuration.
Repeat Steps 7 through 11 on Switch 1 for interface Fa0/2.
Repeat Steps 7 through 11 on Switch 2 to configure the
trunk ports on interface Fa0/1 and Fa0/2.
When the trunk links come up, VTP passes the VTP and
VLAN information to Switch 2. Verify the Switch 2 has
learned the VLAN configuration.
Enter global configuration mode on Switch 1.
Chapter 8
Configuring VLANs
78-6511-05

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ws-c2960g-8tc-l

Table of Contents