Lucent Technologies MERLIN LEGEND Release 7.0 Pocket Reference page 128

Hide thumbs Also See for MERLIN LEGEND Release 7.0:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 7.0
Pocket Reference 555-670-116
Reference Documents
Technical Addendum
Maintenance Error Codes
Error
Code
Description
840B
NO LOOP CURRENT:
Communication problems
between module and CO; no loop
current. If error occurs four times
consecutively and if automatic
maintenance-busy is enabled and
maintenance-busy limit is less
than 50%, trunk is busied-out
automatically.
840C
STUCK RINGING:
Communication problems
between module and CO; no loop
current. If error occurs four times
consecutively and if automatic
maintenance-busy is enabled and
maintenance-busy limit is less
than 50%, trunk is busied-out
automatically.
840D
INCORRECT FIRMWARE
STATE:
If error occurs four times
consecutively and if automatic
maintenance-busy is enabled and
maintenance-busy limit is less
than 50%, trunk is busied-out
automatically.
840E
UPLINK MESSAGE ERROR:
Communication problems
between processor and modules.
Module received unrecognized
message from processor.
840F
LOST IDLE MESSAGE
ERROR:
Loop start trunk lost an idle
message during glare timing.
8C01
SLOTS NOT EQUAL:
Module that occupies indicated
slot does not match slot
information contained in PC or
PCMCIA card backup file.
9801
MCARD WRITE ERROR:
Write to memory card is
unsuccessful or too slow.
9802
MCARD ERASE ERROR:
Erasure of memory card is
unsuccessful or too slow.
—Continued
Action
Replace module with similar
module and test. If problem is
resolved, replace bad module. If
problem persists, reinstall old
module and test trunk.
Replace module with similar
module and test. If problem is
resolved, replace bad module. If
problem persists, reinstall old
module and test trunk.
Turn power off for at least one
second, and then turn it on.
Repeat system programming
procedure. If problem persists,
replace module.
Turn processor off and then on.
Repeat system programming
procedure. If problem persists,
replace module.
System has taken corrective
action. If problem persists,
contact NSAC Tier III.
Check slot descriptions in
backup file against actual
system modules that occupy
slots. After mismatch is
corrected, restore.
Reset card and try again. If
problem persists, replace card
and try again. If problem
continues, replace processor
module.
Reset card and try again. If
problem persists, replace card
and try again. If problem
continues, replace processor
module.
Issue 1
April 1999
122