MERLIN LEGEND Communications System Release 7.0
Pocket Reference 555-670-116
Reference Documents
Maintenance Error Codes
Error
Code
Description
8402
WINK TOO SHORT:
Outbound dialing problems on tie
trunks. Wink from the far end of
network interface is less than 100
ms, the minimum for delay-dial or
wink-start tie trunks. Tie trunk
waits for valid signal.
8403
NO EXTERNAL RELEASE:
Communication problems
between module and CO. Far end
has not disconnected within 4
minutes. If error occurs twice
consecutively, trunk is busied-out
automatically whether or not
automatic maintenance-busy is
enabled.
8404
ON HOOK BEFORE WINK:
Outbound dialing problems on tie
trunks. Far end of network
interface went on-hook before
handshake was completed (for
delay-dial or wink-start tie trunk).
8405
ON HOOK BEFORE READY:
Outbound dialing problems on tie
trunks. Far end of network
interface went on-hook before
guard time elapsed (for delay-dial
or wink-start tie trunk).
8406
INTERDIGIT TOO SHORT:
Inbound dialing problems on tie
and DID trunks.
8407
BAD UPDATE:
Communication problems
between processor and modules;
module may need to be replaced.
8408
ROTARY RATE > 12PPS:
Inbound dialing problems on tie
and did trunks.
8409
ROTARY RATE < 8PPS:
Inbound dialing problems on tie
and did trunks.
840A
BAD DOWNLINK MESSAGE:
Communication problems
between processor and modules;
module received an unrecognized
message from processor.
Technical Addendum
—Continued
Action
Check far end of network.
Check for faulty cable. Replace
module.
Check far end of network
interface. Check for faulty cable.
If problem persists, check tie
trunk configuration. Check far
end. Check for faulty cable.
Replace module.
Check far end of network
interface. Check wink start and
for faulty cable. Check far end of
network. Replace module.
Check far end of network
interface. Check for faulty cable.
Replace module.
Turn processor off and then on.
Repeat system programming
procedure. If problem persists,
contact NSAC Tier III.
Check far end of network
interface. Check for faulty cable.
Replace module.
Check far end of network
interface. Check for faulty cable.
Replace module.
Turn processor off and then on.
Repeat system programming
procedure. If problem persists,
replace module.
Issue 1
April 1999
121