MERLIN LEGEND Communications System Release 7.0
Pocket Reference 555-670-116
Reference Documents
Technical Addendum
Maintenance Error Codes
Error
Code
Description
0010
INVALID SLOT
INTERRUPT:
Cannot determine module
responsible for interrupt.
0011
STACK OVERFLOW:
Processor problem.
0012
INVALID RESET FLAG:
Processor problem.
0013
DUART STREAMING INT:
Processor problem.
0014
PROCESSOR ERR
INTERRUPT:
Processor problem.
0015
MODULE MISMATCH:
Module inserted into wrong slot.
0016
POWER UP COLD START:
Module dual port ram failure;
system programming OK.
0017
REAL TIME CLOCK FAULT:
Date and/or time incorrect or
unreadable.
0018
RTC COLD START:
This error is not displayed.
0019
RESET TIME & DATE:
System cold-starts because real-
time clock chip is not working
correctly.
0401
ABK CARD NOT INSERTED:
PCMCIA memory card for
translation is not inserted.
0402
ABK INCORRECT CARD
TYPE:
PCMCIA memory card for non-
translation is inserted.
0403
ABK CARD WRITE-
PROTECTED:
Translation card has write-
protected switch on.
0404
ABK EXTENSION BUSY:
A station is in program,
administration, or maintenance
mode.
—Continued
Action
Check modules and replace if
necessary; if problem persists,
check processor.
Check processor.
Check processor.
Check processor.
Check processor.
Change system
programming for proper module
or install proper module.
If problem persists, check
module for slot indicated.
If problem persists, replace
processor module.
If problem persists, replace
processor module.
Insert a translation card or an
unformatted card.
Remove current card and insert
a translation card or an
unformatted card.
Turn write-protection switch to
off. If problem persists, try
another card. If still not working,
replace processor module.
Wait until station changes
mode.
Issue 1
April 1999
112