Lucent Technologies MERLIN LEGEND Release 7.0 Pocket Reference page 120

Hide thumbs Also See for MERLIN LEGEND Release 7.0:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 7.0
Pocket Reference 555-670-116
Reference Documents
Technical Addendum
Maintenance Error Codes
Error
Code
Description
0C04 MWL Fac Timeout:
Two consecutive messages to
update Message Waiting lights
have been sent across the private
network for the same tandem trunk
and have not been acknowledged.
When this happens three times,
the error becomes permanent. The
alarm remains in the log until a
message is acknowledged or five
days pass.
0C05 MWL Delivery Delay:
A message to update the Message
Waiting lights has exceeded the
time period for delivery. A transient
alarm occurs after one minute, and
a permanent alarm occurs after 15
minutes. The alarm remains in the
error log until a message is
delivered or five days pass.
1C01 POOL M-BUSY EXCEEDS
50%:
more than half the trunks in pool
are busy.
1C02 DPR TEST NOT COMPLETED:
1C03 FW UPGRADE ATTEMPT:
1C04 FW UPGRADE COMPLETE
—Continued
Action
Check the error log for additional
error codes. If the error log also
contains errors indicating problems
with the 100D and/or 400EM
module, troubleshoot the 100D and/
or the 400EM module (see Chapter
4 of Maintenance and
Troubleshooting) .
If the 100D and/or the 400EM
module are functioning properly,
troubleshoot the trunks using
instructions in Chapter 5 of
Maintenance and Troubleshooting .
Check the error log for additional
error codes. If the error log also
contains errors indicating problems
with the 100D and/or 400EM
module, troubleshoot the 100D and/
or the 400EM module using
instructions in Chapter 4 of
Maintenance and Troubleshooting .
If the 100D and/or the 400EM
module are functioning properly,
troubleshoot the trunks using
instructions in Chapter 5 of
Maintenance and Troubleshooting .
Check that the system receiving the
message had enough TTRs to
handle the volume of calls. Check
the error log on the sending system
and then on the receiving system.
More facilities or TTRs may be
needed.
Check trunk.
Slot did not complete initializing.
No action required.
No action required.
Issue 1
April 1999
114