Lucent Technologies MERLIN LEGEND Release 7.0 Pocket Reference page 124

Hide thumbs Also See for MERLIN LEGEND Release 7.0:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 7.0
Pocket Reference 555-670-116
Reference Documents
Technical Addendum
Maintenance Error Codes
Error
Code
Description
6C10
BRI NET INV 2B+D LB ACT:
Service on link has been lost.
6C11
BRI NET INV B1 LB ACT:
Service on link has been lost.
6C12
BRI NET INV B2 LB ACT:
Service on link has been lost.
6C13
BRI NET INV IL LB ACT:
Service on link has been lost.
6C14
BRI NET INV QM LB ACT:
Service on link has been lost.
7001
PRI SVC AUDIT TIMEOUT:
7002
PRI SVC STATE
INCONSIST:
7003
PRI D-CHNL INOPERATIVE:
7004
PRI B-CHNL NOT
RELEASED:
7005
PRI B-CH GROUP
INCONSIST:
7006
PRI PROTOCOL MISMATCH:
A mismatch in the protocol being
supplied versus the protocol
expected by MERLIN LEGEND.
—Continued
Action
Usually none; link should return
to normal once test is
completed. If problem persists,
contact NSAC Tier III.
Usually none; link should return
to normal once test is
completed. If problem persists,
contact NSAC Tier III.
Usually none; link should return
to normal once test is
completed. If problem persists,
contact NSAC Tier III.
Usually none; link should return
to normal once test is
completed. If problem persists,
contact NSAC Tier III.
Usually none; link should return
to normal once test is
completed. If problem persists,
contact NSAC Tier III.
Check PRI facility and report to
service provider; otherwise, no
action is needed. If problem
persists, contact NSAC Tier III.
Check PRI facility and report to
service provider; otherwise, no
action is needed. If problem
persists, contact NSAC Tier III.
Check PRI facility and report to
service provider; otherwise, no
action is needed. If problem
persists, contact NSAC Tier III.
Check PRI facility and report to
service provider; otherwise, no
action is needed. If problem
persists, contact NSAC Tier III.
Check PRI facility and report to
service provider; otherwise, no
action is needed. If problem
persists, contact NSAC Tier III.
Inform the service provider to
change the administration for
this circuit. After the service
provider restarts the circuit,
verify that all alarms for this slot
are cleared.
Issue 1
April 1999
118

Advertisement

Table of Contents
loading

Table of Contents