MERLIN LEGEND Communications System Release 6.0
Network Reference 555-660-150
5
System Management
Uniform Dial Plan Routing
Valid Entries
Up to 20 digits (any combination of 0 to 9 and HOLD (P), for Pause)
Voice and/or Data Routing
For UDP routing, the voice/data attribute is used in conjunction with PRI tandem
trunks.
The voice/data attribute can be associated with any UDP route.
The factory setting is Voice/Data.
Valid Entries
Voice Only, Data Only, Voice/Data
Task List: Uniform Dial-Plan Routing
o
Obtain Non-Local UDP Administration Form in the Installation
Specification, UDP Routing.
o
Plan changed or new non-local UDP routes using the planning guidelines
above and after consulting other system managers in the network. Record
the new values on the form.
o
Ensure that tandem trunks have been assigned to pools. If necessary,
consult "Trunks to Pools Assignment" in the "Lines and Trunks" section of
System Programming, Chapter 4."
o
Open the System Programming menu from the console or a PC with SPM.
o
Program the change(s), following the instructions below in the order
shown, or those for "UDP Routing" in System Programming , Chapter 4.
o
When you have finished, file the form with the rest of the planning forms.
NOTE:
To avoid confusion and for future planning purposes, tandem trunks
and pools of tandem trunks should be numbered uniquely and
unambiguously.