When you establish the serial connection to the system, press Enter to display the CLI prompt in the
terminal emulation window. For example,
When you see one of these prompts, you are connected to the system and can proceed to
"Assigning permanent passwords"
You can customize the prompt by changing the system name. Refer to the PowerConnect B-Series
TI24X Configuration Guide.
If you do not see a prompt:
The EIA or TIA 232 serial communication port serves as a connection point for management by a
PC or SNMP workstation. Dell switches and Layer 3 Switches come with a standard male DB-9
connector, shown in
FIGURE 8
Most PC serial ports also require a cable with a female DB-9 connector.
Terminal connections will vary, requiring either a DB-9 or DB-25 connector, male or female.
Serial cable options between a Dell switch or router and a PC or terminal are shown in
Dell PowerConnect B-Series TI24X Hardware Installation Guide
53-1002265-01
Flow control: None
PowerConnect>
Make sure the cable is securely connected to your PC and to the PowerConnect B-Series TI24X
device.
Check the settings in your terminal emulation program. In addition to the session settings
listed above, make sure the terminal emulation session is running on the same serial port you
attached to the PowerConnect B-Series TI24X device.
Figure
8.
Serial port pin and signalling details
Pin Assignment
DB-9 male
on page 23.
Pin Number
Attaching a PC or terminal
Switch Signal
1
Reserved
2
TXD (output)
3
RXD (input)
4
Reserved
5
GND
6
Reserved
7
CTS (input)
8
RTS (output)
9
Reserved
2
Figure
9.
21