Electrical Main Service; Wiring Grounding And Bonding; Circuit Breaker Installation And Wiring; General Purpose Outlet - Hayward Pro Logic® Installation Manual

Pro logic series
Hide thumbs Also See for Pro Logic®:
Table of Contents

Advertisement

Remote Display/Keypad
Wireless Base
Connector
Receiver Connector
4 Temp
Sensor Inputs
External Input Interlock
2 Heater Outputs
4 Valve Connectors
Flow Switch
Connector
Cell Connector
Subpanel
The Pro Logic Control Center and PS-16 Expansion Unit require both high and low voltage connections. Low
voltage connections will be made to actuators, sensors, remote keypad, etc. High voltage connections will be
made to pumps, lights, etc., as well as providing direct input power to the Control Center. Always:
-Ensure that Power is disconnected prior to doing any wiring
-Follow all local and NEC (CEC if applicable) codes
-Use copper conductors only
Main Service (Power to the Circuit Breaker Subpanel)
The Pro Logic circuit breaker subpanel is rated for 100A service. Run properly rated conductors (L1, L2, N, and
ground) from the primary house electrical panel to the main power connections on the Pro Logic circuit breaker
base. The connection at the main house panel should be to a 240VAC circuit breaker rated at 100A maximum.
Grounding and Bonding
Connect a ground wire from the primary electrical panel to the Pro Logic ground bus bar. Also ground each piece
of high voltage (120 or 240VAC) equipment that is connected to the Pro Logic control relays or circuit breakers.
The Pro Logic should also be connected to the pool bonding system by an 8AWG (6AWG for Canada) wire. A
lug for bonding (2 for Canada) is provided on the outside/bottom of the Pro Logic enclosure.

Circuit Breaker Installation and Wiring

Circuit breakers are to be supplied by the installer. See the chart below for a list of suitable circuit breakers that
can be used. Follow the code and the circuit breaker manufacturer's rating requirements regarding the size and
temperature rating for wiring. Note that some pool equipment may be required to be connected to ground fault
circuit breakers—check local and NEC (CEC) codes.
Manufacturer
Cutler-Hammer
Murray
Siemens
Square D
Thomas & Betts
G.E.

General Purpose Outlet

If desired, a duplex receptacle with weatherproof cover (supplied by installer) may be installed in the knockouts on
the lower right side of the Pro Logic enclosure. Per code, the receptacle should be a GFCI type. Alternatively,
connect a standard receptacle to a GFCB.
4. Electrical Wiring
4 wire connection between PS-16 and -EXP
AQL-CHEM
Connector
"Local" Display
8 High Voltage Relays
for PS-8, PS-16
(4 relays for PS-4)
Control Power Input
pH Dispense
Output
L2
L1
N
Ground Bus Bar
Bonding Lug(s)
SUITABLE LISTED BREAKERS
Single Double
Twin
BR
BR
BRD
MP-T
MP-T
MH-T
QT
QP
QP
HOM
HOM
HOMT
TB
TB
TBBD
THQL
THQL
4 Valve Connectors
8 High
Voltage Relays
Subpanel
Ground Bus Bar
Quad
GFCB
Filler Plates
BRD
GFCB
BRFP
MH-T
MP-GT
LX100FP
QT
QPF
QF3
HOMFP
HOMT
HOM-GFI
TBBQ
GFB
FP-1C-TB
THQL-GF
TFH
12
To PS-16 Display/Keypad
Connector
For use with
PS-16 only
10
9
8
7
Control Power
L2
L1
N
Expansion Unit
(AQL-PS-16 only)
Tightening
Torque
25lb-in
25lb-in
25lb-in
25lb-in
25lb-in
25lb-in
Input
Bonding
Lug(s)