STA-RITE Heater
1. Turn power off to heater.
2. Remove upper jacket and open the control box.
3. Remove the jumper for the "fireman's switch.
4. Wire to the Pro Logic using wire rated for 105°C minimum.
Fireman's
Switch
Operating
'Control
Terminal
Board
STA-RITE
Hayward Variable Speed Pump (VSP) Wiring and Address Setting
Refer to your TriStar or EcoStar manual(s) for proper low voltage communication wiring between the Pro Logic
and the Hayward Variable Speed Pump.
A pump address must be configured for each VSP used in the system. This address is entered into the VSP's
configuration menu. Refer to the table below to determine which address to use for your specific pump and Pro
Logic. Select the proper address based on which output will be used and the model VSP you are configuring.
Pro Logic Output
This is the output used to control the VSP.
Note that the VSP should be wired to this
output's corresponding relay.
FILTER - all Pro Logic models
AUX1 - all Pro Logic models
Dual Equipment Spa Filter - all models
LIGHTS - all Pro Logic models
A
UX
2 - all Pro Logic models
A
UX
3-A
UX
A
UX
7-A
UX
6 - PS8 & PS16 models
14 - PS16 models
VSP Address
This is the name that should be selected
under "Set COMM bus address" (EcoStar)
or "*H.Comm ADDR." (TriStar) within the
VSP's Configuration Menu.
"001" - Tristar
"Pool Filter" - EcoStar
"002" - Tristar
"
Aux1 / Spa Filter
"Lights Button" - EcoStar only
Aux2-Aux14 - EcoStar only
(use same as Pro Logic Output)
18
" - EcoStar