Configuration Group Function - Hayward Pro Logic® Installation Manual

Pro logic series
Hide thumbs Also See for Pro Logic®:
Table of Contents

Advertisement

After plumbing and wiring are complete, the Pro Logic MUST BE CONFIGURED before attempting to operate.
Configuration information is entered at the keypad and "tells" the Pro Logic what equipment is connected and how
each should be controlled.
Group Function
The latest version of the Pro Logic offers the ability to assign a Group function to a particular button. Instead of a
button controlling one particular function, the button can be programmed to initiate a sequence of commands that
are programmed in the Configuration Menu. For example, instead of the Lights button turning on and off the pool
light only, the button can be programmed to turn on the pool light, turn on the bug light, turn off the pool cleaner, turn
on and dim the patio lights, turn on the music, etc. all at the same time. This convenient feature is offered on all Aux
buttons, both Valve buttons and the Lights button. The Pro Logic can be programmed to control up to four groups.
Refer to this section when programming Group commands.
Before assigning and configuring all the desired functions and their control parameters, the group itself must be
configured. The options for controlling groups are Manual On/Off, Countdown Timer, and Timeclock. The group
will turn on and off based on this selection.
When setting up a Group function in the Configuration Menu, the first menu allows you to select the control
parameter (how the group is activated and de-activated) and the second menu allows you to select which Pro
Logic functions are to be controlled in the group.
A table of functions and their corresponding control parameters are listed below.
Function
Pool/Spa
Pool Filter
Lights
(standard relay)
Lights
(dimmer relay)
Lights
(VSP relay)
Spa Filter
Aux1-14
Aux1-14
Aux1-14
Valve3
Valve4
Spa Htr1 Set
Pool Htr1 Set
Spa Htr2 Set
Pool Htr2 Set
Spa Solar Set
Pool Solar Set
SuperChlr
5. Configuration Setup
Unaffected, Pool only, Spa only, or Spillover
Unaffected, Off, On, High, Low, On (Lowest to Highest)
Unaffected, Off, or On
Unaffected, Off, On (100%, 80%, 60%, 40%, or 20%)
Unaffected, Off or On (10% to 100%)
Unaffected, Off, On, High, Low, On (Lowest to Highest)
Unaffected, Off
(s
tandard relay)
Unaffected, Off, On (100%, 80%, 60%, 40%, or 20%)
(dimmer relay)
Unaffected, Off or On (10% to 100%)
(VSP relay)
Unaffected, Off or On
Unaffected, Off or On
Unaffected, Off, 65º-104ºF
Unaffected, Off, 65º-104ºF
Unaffected, Off, 65º-104ºF
Unaffected, Off, 65º-104ºF
Unaffected, Off, 65º-104ºF
Unaffected, Off, 65º-104ºF
Unaffected, Off, On
Control Parameter
or
On
22