Electrical Main Service; Wiring Grounding And Bonding; Circuit Breaker Installation And Wiring - Hayward Pro Logic PL-P-4-CUL Installation Manual

Automation and chlorination
Table of Contents

Advertisement

Remote Keypad
Temp Sensor Inputs
External Input
Heater Output
Valve Connectors
Flow Switch
The Pro Logic Control Center requires both high and low voltage connections. Low voltage connections will be made
to actuators, sensors, remote keypad, etc. High voltage connections will be made to pumps, lights, etc., as well as
providing direct input power to the Control Center. Always:
-Ensure that Power is disconnected prior to doing any wiring
-Follow all local and NEC (CEC if applicable) codes
-Use copper conductors only
Main Service (Power to the Circuit Breaker Subpanel)
The Pro Logic circuit breaker subpanel is rated for 100A service. Run properly rated conductors (L1, L2, N, and
ground) from the primary house electrical panel to the main power connections on the Pro Logic circuit breaker base.
The connection at the main house panel should be to a 240VAC circuit breaker rated at 100A maximum.
Grounding and Bonding
Connect a ground wire from the primary electrical panel to the Pro Logic ground bus bar. Also ground each piece of
high voltage (120 or 240VAC) equipment that is connected to the Pro Logic control relays or circuit breakers. The
Pro Logic should also be connected to the pool bonding system by an 8AWG (6AWG for Canada) wire. A lug for
bonding (2 for Canada) is provided on the outside/bottom of the Pro Logic enclosure.

Circuit Breaker Installation and Wiring

Circuit breakers are to be supplied by the installer. Refer to the circuit breaker chart below for a list of suitable circuit
breakers that can be used. Follow the code and the circuit breaker manufacturer's rating requirements regarding the
size and temperature rating for wiring. Note that some pool equipment may be required to be connected to ground
fault circuit breakers—check local and NEC (CEC) codes.
4. Electrical Wiring
Wireless Base
Receiver Connector
x
x
Cell Connector
Subpanel
SUITABLE LISTED BREAKERS
Manufacturer
Single Double
Cutler-Hammer
BR
BR
MP-T
MP-T
Murray
Siemens
QP
QP
Square D
HOM
HOM
TB
TB
Thomas & Betts
G.E.
THQL
THQL
AQL-CHEM Connector
Ground Bus Bar
Twin
Quad
Filler Plates
GFCB
BRD
GFCB
BRFP
BRD
LX100FP
MH-T
MH-T
MP-GT
QT
QT
QPF
HOMT
HOM-GFI
HOMFP
HOMT
FP-1C-TB
TBBD
TBBQ
GFB
THQL-GF
10
"Local" Display
High Voltage
Relays
Control Power
Input
pH Dispense
Output
Bonding Lug(s)
Tightening
Torque
25lb-in
25lb-in
QF3
25lb-in
25lb-in
25lb-in
TFH
25lb-in