Fcoe Converged Network Switch Data Flow Latency; Fibre Channel Port Specifications; Post And Boot Specifications; Post - HP StorageWorks 8/40 - SAN Switch Hardware Reference Manual

Storageworks 8-gb san switch series
Hide thumbs Also See for StorageWorks 8/40 - SAN Switch:
Table of Contents

Advertisement

FCoE Converged Network Switch data flow latency

Table 29
describes the data flow latency for the FCoE Converged Network Switch.
Table 29 Data flow latency for the FCoE Converged Network Switch
Data flow
latency Type
FC port to FC
port
CEE port to
CEE port
(same ASIC)
CEE port to
CEE port (dif-
ferent ASIC)
FCoE to FC

Fibre Channel port specifications

The Fibre Channel ports in the 8-Gb SAN Switch are compatible with SWL, LWL, and ELWL SFP
transceivers. The strength of the signal is determined by the type of transceiver in use.
The ports meet all required safety standards.
The ports are capable of operating at 1, 2, 4, or 8 Gb/s and are able to autonegotiate to the maximum
link speed.

POST and boot specifications

The switch performs POST by default each time it is powered on or rebooted or the system is reset.
Boot time with POST is usually about 1 to 3 minutes.
POST can be skipped after subsequent reboots by entering the fastBoot command. For more
information about this command, see the Fabric OS Command Reference Manual.

POST

The success/fail results of the diagnostic tests that run during POST can be monitored through LED
activity, the error log, or the CLI.
POST:
Conducts preliminary POST diagnostics.
Initializes the operating system.
Initializes hardware.
Runs diagnostic tests on several functions, including circuitry, port functionality, memory, statistics
counters, and serialization.
90
Technical Specifications
Size in nano-
seconds
+/– 700 ns
570 ns
91,050 ns
1,670 ns

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents